IBM 4560SLX User Guide - Page 105
Voltage limits, Frequency limits, Power requirements, Sag/Surge protection, Power line disturbance
UPC - 087944855910
View all IBM 4560SLX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
Voltage limits The 4560SLX Tape Library is capable of using any nominal ac voltage between 100 and 240 V ac power, at 50 or 60 Hz. It is capable of powering up and operating without error from any voltage within the ranges specified: Frequency limits The 4560SLX Tape Library is capable of operation at either 50 Hz or 60 Hz. It will automatically adjust for 50-60 Hz primary power operation, without requiring user intervention or modification. Power requirements The 4560SLX Tape Library (with two tape drives installed) exhibits a nominal steady state ac power consumption of 192 watts, and a maximum peak power consumption of 240 watts. Table 24. Current Current 4560SLX Tape Library 1.6 - 1.0 A (120 V ac - 240 V ac) Sag/Surge protection Once powered on, the 4560SLX Tape Library will continue to operate without error under the following conditions: Table 25. Sag/Surge protection Condition 100 V -20% 120 V +15% 200 V -20% 240 V -20% Period 2 seconds 1 second 2 seconds 2 seconds Power line disturbance Once powered on, the 4560SLX Tape Library will continue to operate without error under the following conditions of power line disturbances: Table 26. Power line disturbance Disturbance PULSE: 1.2 ms rise - 50 ms decay 8.0 ms rise - 20 s decay RING: 0.5 ms @ 100 KHz Period High Low High Low Limit 1.0 KV, Max 300 A, Max 1.0 KV, Max 200 A, Max Appendix C. Specifications 95