Icom IC-80AD Instruction Manual - Page 96
Alarm area 1
View all Icom IC-80AD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
8 GPS/GPS-A OPERATION D Alarm area 1 Sets GPS alarm active range from 00.08′ to 59.99′ in 00.01′ steps. (default: 00.25′) q Enter "ALM1" in GPS set mode. MENU ¶ GPS ¶ ALM1 (Push [MENU ]), (Push [ ](2)/[ ](8), then push [ ](5).) • ALM1 setting screen is displayed. • Example: Your position : 35°N/135°E ALM AREA1 setting : 00.25' (default) Point A 00.25' 00.25' N Point B Your position 00.25' 00.25' When "P FORM" (position format) (p. 136) is selected "mm.mm." When "P FORM" (position format) (p. 136) is selected "mm.SS." w Push [ ](2) or [ ](8) to set the desired alarm area. • Push [ ](6) to move the cursor right; push [ ](4) to move the cursor left. e Push [ ](5) to set the area. r Push [MENU ] to return to frequency indication. The alarm area 1 function is available when the "GPS ALARM" function ALL is ON. 88 Point C • Position of point A • Position of point B • Position of point C • Position of point D Point D : 35°00.25'N/134°59.75'E : 35°00.25'N/135°00.25'E : 34°59.75'N/134°59.75'E : 34°59.75'N/135°00.25'E When the target position comes into the alarm area shown above, the GPS alarm sounds. These sample indications assume that "P FORM" is selected "mm.mm." (p. 136)