Page 38 highlights
6 MENU MODE OPERATION ■ Menu mode items D CPA/TCPA (Continued) • CPA, TCPA Enter CPA (Closest Point of Approach) and TCPA (Time to CPA) values. These settings help you find a dangerous target to avoid a collision. The icon blinks on the plotter display and/or the alarm buzzer sounds, when the AIS target is closer than your CPA and TCPA settings. q Push [∫] or [√] to select either "CPA" or "TCPA." w Push [Ω] or [≈] to input the value into that item. • CPA : Between 0.1 and 6.0 nm (in 0.1 nm steps) (default: 1.5 nm) • TCPA : Between 1 and 60 minutes (in 1 minute steps) (default: 20 min) e R epeat steps q and w to input the value into the other item. r Push [CLEAR] to save and return to the Menu mode. ENT] [CLEAR] D Own Static This screen shows your static vessel information such as MMSI code, Vessel Name, Call Sign, Internal/External GPS antenna position and Type of Ship. q W hen the Own Static screen is displayed, push [≈] to select the next page, or push [Ω] to select the previous page. w Push [CLEAR] to return to the Menu mode. 30