Intel BOXD925XBCLK Product Specification - Page 37

Hardware Management Subsystem

Page 37 highlights

Product Description 1.13 Hardware Management Subsystem The hardware management features enable the Desktop Boards to be compatible with the Wired for Management (WfM) specification. The Desktop Board has several hardware management features, including the following: • Fan monitoring and control (through the hardware monitoring and fan control ASIC) • Thermal and voltage monitoring • Chassis intrusion detection 1.13.1 Hardware Monitoring and Fan Control ASIC The features of the hardware monitoring and fan control ASIC include: • Internal ambient temperature sensor • Two remote thermal diode sensors for direct monitoring of processor temperature and ambient temperature sensing • Power supply monitoring of five voltages (+5 V, +12 V, +3.3 VSB, +1.5 V, and +VCCP) to detect levels above or below acceptable values • Thermally monitored closed-loop fan control, for all three fans, that can adjust the fan speed or switch the fans on or off as needed • SMBus interface For information about The location of the fan connectors and sensors for thermal monitoring for the D925XCV board The location of the fan connectors and sensors for thermal monitoring for the D925XBC board Refer to Figure 15, page 38 Figure 16, page 39 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Product Description
37
1.13 Hardware Management Subsystem
The hardware management features enable the Desktop Boards to be compatible with the Wired
for Management (WfM) specification.
The Desktop Board has several hardware management
features, including the following:
Fan monitoring and control (through the hardware monitoring and fan control ASIC)
Thermal and voltage monitoring
Chassis intrusion detection
1.13.1
Hardware Monitoring and Fan Control ASIC
The features of the hardware monitoring and fan control ASIC include:
Internal ambient temperature sensor
Two remote thermal diode sensors for direct monitoring of processor temperature and ambient
temperature sensing
Power supply monitoring of five voltages (+5 V, +12 V, +3.3 VSB, +1.5 V, and +VCCP) to
detect levels above or below acceptable values
Thermally monitored closed-loop fan control, for all three fans, that can adjust the fan speed or
switch the fans on or off as needed
SMBus interface
For information about
Refer to
The location of the fan connectors and sensors for thermal monitoring for
the D925XCV board
Figure 15, page 38
The location of the fan connectors and sensors for thermal monitoring for
the D925XBC board
Figure 16, page 39