Intel P8700 Product Manual - Page 1
Intel P8700 - Core 2 Duo Processor Manual
UPC - 735858206174
View all Intel P8700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
1/16 - 1/8 - 1/4 DIN LIMIT CONTROLLERS CONCISE PRODUCT MANUAL (59333-2) CAUTION: Installation should be only performed by technically competent personnel. Local Regulations regarding electrical installation & safety must be observed. 1. INSTALLATION The models covered by this manual have three different DIN case sizes (refer to section 9). Some installation details vary between models. These differences have been clearly shown. Note: The functions described in sections 2 thru 8 are common to all models. Installing Option Modules 1/16 Din Size Instruments CPU PCB Mounting Struts Option Module 1 (Fixed Limit Relay) Option Module 2 Option Module A Option Module 3 1/8 & 1/4 Din Size Instruments PSU PCB CPU PCB Option Module B (not used on Limit Controllers) Option Module 2 Option Module 1 (Fixed Limit Relay) Mounting Struts Option Module A Option Module 3 PSU PCB To access module A, first detach the PSU and CPU boards from the front by lifting first the upper, and then lower mounting struts. Gently separate the boards. a. Plug the required option modules into the correct connectors, as shown below. b. Locate the module tongues in the corresponding slot on the opposite board. c. Hold the main boards together while relocating back on the mounting struts. d. Replace the instrument by aligning the CPU and PSU boards with their guides in the housing, then slowly push the instrument back into position. Note: Option modules are automatically detected at power up. Option Module Connectors 1/16 Din Size Instruments Option Slot 1 (Fixed Limit Relay) Option Slot A Connectors PL5 & PL6 Option Slot 2 Connector PL4A Option Slot 3 Connector PL4B Option Slot B (not used on Limit Controllers) Option Slot 2 Connector PL4A Option Slot 1 (Fixed Limit Relay) 1/8 & 1/4 Din Size Instruments Option Slot A Connectors PL5 & PL6 Option Slot 3 Connector PL4B Panel-Mounting The mounting panel must be rigid, and may be up to 6.0mm (0.25inch) thick. Cut-out sizes are: Cut-Out Dim A 1/16 & 1/8 Din = 45mm 1/4 Din = 92mm Cut-Out Dim B 1/16 Din = 45mm 1/8 & 1/4 Din = 92mm For n multiple instruments mounted side-by-side, cut-out A is 48n-4mm (1/16 & 1/8 Din) or 96n-4mm (1/4 Din) B A Tolerance +0.5, -0.0mm Mounting Panel Instrument Housing Ratchets Slide mounting clamp over the instrument housing towards rear face of mounting panel until the tongues engage in ratchets and instrument is clamped in position. Gasket Hold instrument firmly in position (apply pressure to bezel only) CAUTION: Do not remove the panel gasket; it is a seal against dust and moisture. Rear Terminal Wiring USE COPPER CONDUCTORS (EXCEPT FOR T/C INPUT) Single Strand wire gauge: Max 1.2mm (18SWG) 1/16 Din Size Instruments 1/8 & 1/4 Din Size Instruments These diagrams show all possible option combinations. The actual connections required depends on the exact model and options fitted. CAUTION: Check information label on housing for correct operating voltage before connecting supply to Power Input Fuse: 100 - 240V ac - 1amp anti-surge 24/48V ac/dc - 315mA anti-surge Note: At first power-up the message is displayed, as described in section 6 of this manual. Access to other menus is denied until configuration mode is completed 2. SELECT MODE Select mode is used to access the configuration and operation menu functions. It can be accessed at any time by holding down and pressing . In select mode, press or to choose the required mode, press to enter. An unlock code is required to prevent unauthorised entry to Configuration, & Setup modes. Press or to enter the unlock code, then press to proceed. Mode Upper Lower Display Display Description Default Unlock Codes Operator Normal operation None Set Up Tailor settings to the application Configuration Configure the instrument for use Product Info Check manufacturing information None Note: The instrument will always return automatically to Operator mode if there is no key activity for 2 minutes. 3. CONFIGURATION MODE First select Configuration mode from Select mode (refer to section 2). Press to scroll through the parameters, then press or to set the required value. Press to accept the change, otherwise parameter will revert to previous value. To exit from Configuration mode, hold down and press , to return to Select mode. Note: Parameters displayed depends on how instrument has been configured. Refer to user guide (available from your supplier) for further details. Parameters marked * are repeated in Setup Mode. Parameter Lower Upper Adjustment range & Description Display Display Default Value Input Range/Type See following table for possible codes Code Input Type & Range Code Input Type & Range Code Input Type & Range bC B: 100 - 1824 ºC bF B: 211 - 3315 ºF L.C L: 0.0 - 537.7 ºC L.F L: 32.0 - 999.9 ºF PtRh20% vs 40%: P24F 32 - 3362 ºF CC C: 0 - 2320 ºC NC N: 0 - 1399 ºC PTC Pt100: -199 - 800 ºC CF C: 32 - 4208 ºF NF N: 32 - 2551 ºF PtF Pt100: -328 - 1472 ºF JC J: -200 - 1200 ºC rC R: 0 - 1759 ºC Pt.C Pt100: -128.8 - 537.7 ºC JF J: -328 - 2192 ºF rF R: 32 - 3198 ºF Pt.F Pt100: -199.9 - 999.9 ºF j.C J: -128.8 - 537.7 ºC SC S: 0 - 1762 ºC 0 - 20 mA DC j.F J: -199.9 - 999.9 ºF SF S: 32 - 3204 ºF 4 - 20 mA DC KC K: -240 - 1373 ºC tC T: -240 - 400 ºC 0 - 50 mV DC KF K: -400 - 2503 ºF tF T: -400 - 752 ºF . 10 - 50 mV DC k.C K: -128.8 - 537.7 ºC t.C T: -128.8 - 400.0 ºC 0 - 5 V DC K.F K: -199.9 - 999.9 ºF t.F T: -199.9 - 752.0 ºF 1 - 5 V DC LC L: 0 - 762 ºC LF L: 32 - 1403 ºF PtRh20% vs. 40%: P24C 0 - 1850 ºC 0 - 10 V DC 2 - 10 V DC Note: Decimal point shown in table indicates temperature resolution of 0.1° Parameter Lower Upper Adjustment range & Description Default Display Display Value Scale Range Upper Limit Scale Range Lower Limit +100 to Range Maximum Range max (Lin=1000) Scale Range Lower Limit Range Minimum to Scale Range Upper Limit -100 Range min (Linear=0) Decimal point position Process Variable Offset Limit Action Setpoint Upper Limit Setpoint Lower Limit =XXXX, =XXX.X, =XX.XX, =X.XXX (non-temperature ranges only) ±Span of controller (see CAUTION note at end of section) High Limit. Limit relay is energised when process "safe" (PV < Limit Setpoint) Low Limit. Limit relay is energised when process "safe" (PV > Limit Setpoint) Current Setpoint to Scale Range maximum Scale Range minimum to Current Setpoint Process High Alarm R/max R/min Process Low Alarm Alarm 1Type Deviation Alarm Band Alarm High Alarm 1 value* Low Alarm 1 value* Band Alarm 1 value* Dev. Alarm 1 value* Alarm 1 Hysteresis* No alarm Scaled Range Minimum to scaled Range Maximum in display units Range Max Range Min 1 LSD to span from setpoint in display units +/- Span from setpoint in display units ! 1 LSD to full span in display units Parameter Lower Upper Adjustment range & Description Display Display Default Value Alarm 2 Type* High Alarm 2 value* Low Alarm 2 value* Band Alarm 2 value* Dev. Alarm 2 Value* Alarm 2 Hysteresis* ! Options as for alarm 1 Range Max Range Min Mm Limit Output Relay " Alarm 1, Direct Alarm 1, Reverse Alarm 2, Direct Alarm 2, Reverse Output 2 Usage # Logical Alarm 1 OR 2, Direct " Logical Alarm 1 OR 2, Reverse Logical Alarm 1 AND 2, Direct Logical Alarm 1 AND 2, Reverse Limit Annunciator, Direct Limit Annunciator, Reverse Retransmit Limit SP Output Retransmit PV Output 0 to 5 V DC output 1 Linear Output 2 Range ! 0 to 10 V DC output 2 to 10 V DC output 0 to 20 mA DC output 4 to 20 mA DC output Retransmit Output 2 Scale maximum -1999 to 9999 (display value at which output will be maximum) Range max Retransmit Output 3 Scale minimum -1999 to 9999 (display value at which output will be minimum) Range min Output 3 Usage # As for output 2 " Linear Output 3 Range ! As for output 2 Retransmit Output 3 Scale maximum -1999 to 9999 (display value at which output will be maximum) Range max Retransmit Output 3 Scale minimum -1999 to 9999 (display value at which output will be minimum) Range min PV is visible in Operator mode Display Strategy $ PV not visible in Operator mode Displays in Operator mode when Limit Output is not active % ASCII Serial Communications Protocol Mm Modbus with no parity Mm Modbus with Even Parity Mm Mm Modbus with Odd Parity . 1.2 kbps Serial . 2.4 kbps Communications Bit Rate .& 4.8 kbps .& '.( 9.6 kbps '. 19.2 kbps Comms Address 1 to 255 (Modbus), 1 to 99 (ASCII) Comms Write Ww Read/Write Read only Ww Configuration Lock Code ) 0 to 9999 Notes: Output 1 is always a Latching Limit Relay output. If Option Slot A has the Digital Input module fitted, this always functions as a Remote Reset, duplicating the function of the Reset) key . As these functions cannot be changed, no Configuration menus are required. CAUTION: Process Variable Offset can be used to modify the measured value to compensate for probe errors. Positive values increase the reading, negative values are subtracted. This parameter is effectively, a calibration adjustment and MUST be used with care. There is no front panel indication of when this parameter is in use.