Intel RS2WC080 Hardware User Guide - Page 13

Usability, Advanced Array configuration and Management Utilities provides - oce

Page 13 highlights

All operating systems supported by the RAID controller may not be supported by your server board. To verify compatibility, see the Tested Operating System List for your server board at http://www.intel.com/support/motherboards/server/. To make sure the RAID controller supports your operating system, refer to the Tested Hardware and Operating System List for the Intel® RAID Controller RS2WC080. Usability • The card ships with both a standard and a low-profile bracket. • Small, thin cabling with up to 6.0 Gb/s serial, point-to-point data transfer rates • Support for non-disk devices and mixed capacity drives • Support for intelligent XOR RAID levels 0, 1, 5, 10, and 50 • Dedicated or global hot spare with auto rebuild if an array drive fails • User-defined strip size per drive: 8, 16, 32, or 64 KB • Advanced Array configuration and Management Utilities provides: - Online Capacity Expansion (OCE) adds space to existing drive or new drive. See Appendix A for limitations on OCE and RAID migration. - Online RAID level migration (upgrade of RAID mode may require OCE). - Drive migration - Drive roaming - No reboot necessary after expansion - Load Balancing • Upgradeable Flash ROM interface • Allows for staggered spin up, hot-plug, and lower power consumption • User-specified rebuild rate (percent of system resources to use from 0-100%) Caution: Exceeding 50% rate may cause operating system errors due to waiting for controller access. • Background operating mode can be set for Rebuilds, Consistency Checks, Initialization (auto restarting Consistency Check on redundant volumes), Migration, OCE, and Patrol Read. • Allows mixed connections to SAS targets or SATA II targets Note: Intel recommends that you carefully assess any decision to mix SAS and SATA drives within the same virtual drive. Although you can mix drives within the same virtual drive, Intel strongly discourages the practice. However, you should never mix SAS and SATA drives within the same enclosure. Intel® RAID Controller RS2WC080 Hardware User's Guide 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Intel® RAID Controller RS2WC080 Hardware User’s Guide
3
All operating systems supported by the RAID controller may not be supported by your
server board. To verify compatibility, see the
Tested Operating System List
for your server
board at
.
To make sure the RAID controller supports your operating system, refer to the
Tested
Hardware and Operating System List
for the Intel
®
RAID Controller RS2WC080.
Usability
The card ships with both a standard and a low-profile bracket.
Small, thin cabling with up to 6.0 Gb/s serial, point-to-point data transfer rates
Support for non-disk devices and mixed capacity drives
Support for intelligent XOR RAID levels 0, 1, 5, 10, and 50
Dedicated or global hot spare with auto rebuild if an array drive fails
User-defined strip size per drive: 8, 16, 32, or 64 KB
Advanced Array configuration and Management Utilities provides:
Online Capacity Expansion (OCE) adds space to existing drive or new drive.
See Appendix A for limitations on OCE and RAID migration.
Online RAID level migration (upgrade of RAID mode may require OCE).
Drive migration
Drive roaming
No reboot necessary after expansion
Load Balancing
Upgradeable Flash ROM interface
Allows for staggered spin up, hot-plug, and lower power consumption
User-specified rebuild rate (percent of system resources to use from 0-100%)
Caution:
Exceeding 50% rate may cause operating system errors due to waiting for
controller access.
Background operating mode can be set for Rebuilds, Consistency Checks,
Initialization (auto restarting Consistency Check on redundant volumes), Migration,
OCE, and Patrol Read.
Allows mixed connections to SAS targets or SATA II targets
Note:
Intel recommends that you carefully assess any decision to mix SAS and SATA drives
within the same virtual drive. Although you can mix drives within the same virtual drive,
Intel strongly discourages the practice. However, you should never mix SAS and SATA
drives within the same enclosure.