Enterprise Platforms and Services Marketing Monthly Specification Update 10. Integrated BMC Web Console - Power Statistics page - Minimum wattage reads as zero Problem On some systems the Integrated BMC Web Console Power Statistic page may display the Minimun wattage as zero (0W) after the system has been powered. This reading will stay at zero until the next power cycle of the system. Implication Status This is an incorrect reading only and does not affect operation. This issue was fixed in BMC 01.10.3560 and later version. Workaround None. 11. Integrated BMC Web Console - Power Control page - Perform Action button not functional Problem After performing a Graceful shutdown from the Integrated BMC Web Console Power Control page the Perform Action button gets grayed out and cannot be pressed to request another action. Implication You cannot perform a power on of the system. Status This issue was fixed in BMC 01.10.3560 and later version. Workaround Select another page in the Integrated BMC Web Console and then return to the Power Control Page. The Perform Action button will then be available. 12. IPMI Get Chassis Status command returns incorrect Chassis Identify State Problem When a Get Chassis Status command is issued, after the Chassis Identify LED has been forced on, the status of off (00b) is returned for Chassis Identify State (response data byte 4 - bits [5:4]). Implication Unable to correctly read when the Chassis Identify LED is on. Status This issue was fixed in BMC 01.10.3560 and later version. Workaround None. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

Enterprise Platforms and Services Marketing
Monthly Specification Update
7
10.
Integrated BMC Web Console – Power Statistics page – Minimum
wattage reads as zero
Problem
On some systems the Integrated BMC Web Console Power Statistic page may
display the Minimun wattage as zero (0W) after the system has been powered.
This reading will stay at zero until the next power cycle of the system.
Implication
This is an incorrect reading only and does not affect operation.
Status
This issue was fixed in BMC 01.10.3560 and later version.
Workaround
None.
11.
Integrated BMC Web Console – Power Control page – Perform Action
button not functional
Problem
After performing a Graceful shutdown from the Integrated BMC Web Console
Power Control page the Perform Action button gets grayed out and cannot be
pressed to request another action.
Implication
You cannot perform a power on of the system.
Status
This issue was fixed in BMC 01.10.3560 and later version.
Workaround
Select another page in the Integrated BMC Web Console and then return to the
Power Control Page. The Perform Action button will then be available.
12.
IPMI Get Chassis Status command returns incorrect Chassis Identify
State
Problem
When a Get Chassis Status command is issued, after the Chassis Identify LED
has been forced on, the status of off (00b) is returned for Chassis Identify State
(response data byte 4 – bits [5:4]).
Implication
Unable to correctly read when the Chassis Identify LED is on.
Status
This issue was fixed in BMC 01.10.3560 and later version.
Workaround
None.