Recommend to install following RAID Controllers in PCI Slot other than, Slot 4
View all Intel S5000VSA4DIMM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
Intel® Server Boards S5000PSL/S5000XSL, Intel® Workstation Board S5000XVN, and Intel® Server System SC5400RA Installation Guidelines Status: 13. Type "mount /dev/sdb /temp". 14. Type "ls /temp" All the driver files are now in /temp. 15. Type "cd temp" to go to /temp directory. 16. Type "./replace_ahci.sh" to execute the file. This removes ahci from /etc/modprobe.conf and blacklists ahci in /etc/modprobe.d/blacklist. 17. Go back to the graphic screen and reboot the system in order to finish the installation. ESRTII driver ver. 10.21.0507.2008 now has the updated release notes. 6.5 Recommend to install following RAID Controllers in PCI Slot other than Slot 4 Issue: Intel® RAID Controllers SRCSASJV, SRCSASRB, SRCSATAWB, SRCSASBB8I and SRCSASLS4I may fail to activate RAID BIOS Console by Ctrl+G after they are installed into PCI Slot 4 on the Intel® Server Boards S5000PSL, S5000XSL, S5000VSA, or Intel® Workstation Board S5000XVN. Guideline: Install the RAID controller in a different PCI Express Slot. Status: This issue was resolved with BIOS R0094. Revision 2.9 63