Intermec CK3X Intermec RFID Demo User Guide - Page 33

Protect a Tag, About the Write, Error Messages on Define a Data Field to Read

Page 33 highlights

Chapter 2 - Write a Tag 7 View the results of the write. • If the write is successful, a table displays the EPC value of the tag and a "WROK" (Write OK) message. • If the write is unsuccessful, a table displays the EPC value of the tag with an error. For a list of errors, see "About the Write Error Messages" on page 36. 8 (Optional) To verify that the kill password was written successfully: a Set the application to read the kill password. For help, see "Define a Data Field to Read" on page 8. b Read the tag. For help, see "Read a Single Tag" on page 11. c View the tag details field. For help, see "View Tag Field Details" on page 12. Protect a Tag You can use the Intermec RFID Demo to protect an EPC value, user memory, access password, or kill password you have written to a tag. You must first program and protect the access password in order to perform this procedure. To protect a tag 1 If you already launched the Intermec RFID Demo, continue with Step 2. If not, from the Start or Home screen, tap Intermec RFID Demo. 2 Tap Menu > Write. The Write Mode tab appears. 3 From the Program drop-down menu, select one of the following: • EPC • User memory • Access password • Kill password 4 From the drop-down menu, select Protect. 5 In the Data field, enter the access password you recently programmed. The password must be 4 bytes. Intermec RFID Demo User Guide 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Chapter 2 — Write a Tag
Intermec RFID Demo User Guide
27
7
View the results of the write.
If the write is successful, a table displays the EPC value of the
tag and a “WROK” (Write OK) message.
If the write is unsuccessful, a table displays the EPC value of
the tag with an error. For a list of errors, see
“About the Write
Error Messages” on page 36
.
8
(Optional) To verify that the kill password was written
successfully:
a
Set the application to read the kill password. For help, see
“Define a Data Field to Read” on page 8
.
b
Read the tag. For help, see
“Read a Single Tag” on page 11
.
c
View the tag details field. For help, see
“View Tag Field
Details” on page 12
.
Protect a Tag
You can use the Intermec RFID Demo to protect an EPC value, user
memory, access password, or kill password you have written to a tag.
You must first program and protect the access password in order to
perform this procedure.
To protect a tag
1
If you already launched the Intermec RFID Demo, continue with
Step 2. If not, from the Start or Home screen, tap
Intermec RFID
Demo
.
2
Tap
Menu
>
Write
. The
Write Mode
tab appears.
3
From the
Program
drop-down menu, select one of the following:
EPC
User memory
Access password
Kill password
4
From the drop-down menu, select
Protect
.
5
In the
Data
field, enter the access password you recently
programmed. The password must be 4 bytes.