8 SETUP/MAINTENANCE  Visually inspect to ensure the connection is properly made. Connectors MUST be fully engaged. 9. Place the battery retainer assembly on head portion of the mounting screws that secure the shocks to the base frame. ƽ WARNING Wheelchairs with TRRO or TRBKTS Only - Battery support brackets MUST be installed at all times. Otherwise, the wheelchair will not be WC/19 compliant. CAUTION The battery retainer assembly MUST be locked securely to hold the battery boxes firmly in place or battery box connectors may be damaged causing erratic wheelchair operation. 10. Rotate the levers of the battery retainer assembly to the locked position. 11. Wheelchairs with TRRO or TRBKTS Only - Perform the following steps: A. Position the lower battery retainer bracket as shown in Detail "A" of FIGURE 1. B. Install the top battery retainer bracket onto the wheelchair frame using four long hex screws and washers. Torque to 13 ft-lbs. C. Secure the top battery retainer bracket to the lower battery retainer bracket using three short hex screws and washers. Torque to 13 ft-lbs. D. Install the front battery retainer bracket using three bolts and washers. Torque to 13 ft-lbs. Invacare 3G Storm Series® 88 Part No 1143151

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

8
SETUP/MAINTENANCE
Invacare 3G Storm Series®
88
Part No 1143151
9.
Place the battery retainer assembly on head portion of the mounting screws that secure the shocks to the base frame.
10.
Rotate the levers of the battery retainer assembly to the locked position.
11.
Wheelchairs with TRRO or TRBKTS Only - Perform the following steps:
A.
Position the lower battery retainer bracket as shown in Detail “A” of
FIGURE 1
.
B.
Install the top battery retainer bracket onto the wheelchair frame using four long hex screws and washers. Torque to 13 ft-lbs.
C.
Secure the top battery retainer bracket to the lower battery retainer bracket using three short hex screws and washers. Torque to 13 ft-lbs.
D.
Install the front battery retainer bracket using three bolts and washers. Torque to 13 ft-lbs.
Visually inspect to ensure the connection is properly made. Connectors MUST be fully engaged.
±
WARNING
Wheelchairs with TRRO or TRBKTS Only - Battery support brackets MUST be installed at all times. Otherwise, the
wheelchair will not be WC/19 compliant.
CAUTION
The battery retainer assembly MUST be locked securely to hold the battery boxes firmly in place or battery box
connectors may be damaged causing erratic wheelchair operation.