12.13 G-Gain :'U0D'(55H 30H 44H) Definition :Adjusts the G-gain Command Parameter type Reply time Conditions :'U0D'(55H 30H 44H) :Numeric, :3seconds :Computer Sources (Areas) Operation mode Standby mode Power ON mode Cool-down mode X O X Emergency mode X # Communication Examples ◇ When specifying "-2" (decimal) as the G-gain adjust level CTLR DLA '!' '1' SP 'U0D' SP 'FFFE' CR '@' '1' SP '0' CR ◇ When requesting current G-gain adjust level data (if G-gain adjust level is set to "128" (decimal)) CTLR DLA '?' '1' SP 'U0D' CR '@' '1' SP '0' SP '0080' CR 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

27
12.13
G-Gain
:
U0D
(55H
30H
44H)
Definition
Adjusts the G-gain
Command
’U0D’(55H
30H
44H)
Parameter type
Numeric,
Reply time
3seconds
Conditions
Computer Sources (Areas)
Operation mode
Standby mode
Power ON mode
Cool-down mode
Emergency mode
X
O
X
X
#
Communication Examples
When specifying "-2" (decimal) as the G-gain adjust level
CTLR
‘!’
‘1’
SP
‘U0D’
SP
‘FFFE’
CR
DLA
‘@’
‘1’
SP
‘0’
CR
When requesting current G-gain adjust level data (if G-gain adjust level is set to "128" (decimal))
CTLR
‘?’
‘1’
SP
‘U0D’
CR
DLA
‘@’
‘1’
SP
‘0’
SP
‘0080’
CR