JVC DLA-M2000LU Serial protocol for the DLA-DS1U and DLA-M2000LU/SC D-ILA proj - Page 29
B-Gain
View all JVC DLA-M2000LU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
12.14 B-Gain :'U0E'(55H 30H 45H) Definition :Adjusts the B-gain Command Parameter type Reply time Conditions :'U0E'(55H 30H 45H) :Numeric, :3seconds :Computer Sources (Areas) Operation mode Standby mode Power ON mode Cool-down mode Emergency mode X O X X # Communication Examples ◇ When specifying "-2" (decimal) as the B-gain adjust level CTLR DLA '!' '1' SP 'U0E' SP 'FFFE' CR '@' '1' SP '0' CR ◇ When requesting current B-gain adjust level data (if B-gain adjust level is set to "128" (decimal)) CTLR DLA '?' '1' SP 'U0E' CR '@' '1' SP '0' SP '0080' CR 28
28
12.14
B-Gain
:
’
U0E
’
(55H
30H
45H)
Definition
:
Adjusts the B-gain
Command
:
’U0E’(55H
30H
45H)
Parameter type
:
Numeric,
Reply time
:
3seconds
Conditions
:
Computer Sources (Areas)
Operation mode
Standby mode
Power ON mode
Cool-down mode
Emergency mode
X
O
X
X
#
Communication Examples
◇
When specifying "-2" (decimal) as the B-gain adjust level
CTLR
‘!’
‘1’
SP
‘U0E’
SP
‘FFFE’
CR
DLA
‘@’
‘1’
SP
‘0’
CR
◇
When requesting current B-gain adjust level data (if B-gain adjust level is set to "128" (decimal))
CTLR
‘?’
‘1’
SP
‘U0E’
CR
DLA
‘@’
‘1’
SP
‘0’
SP
‘0080’
CR