Kenwood KAC-X542 Instruction Manual - Page 4

Connection - fuse

Page 4 highlights

901 01 901 01 901 01 01 Connection * Commercially available parts 2 WARNING To prevent fire caused by a short in the wiring, connect a fusible link or breaker nearby the battery's positive terminal. 2 CAUTION • If sound is not output normally, immediately turn power off and check connections. • Be sure to turn the power off before changing the setting of any switch. • If the fuse blows, check wires for shorts, then replace the fuse with one of the same rating. • Check that no unconnected wires or connectors are touching the car body. Do not remove caps from unconnected wires or connectors to prevent short circuits. • Connect the speaker wires to appropriate speaker connectors separately. Sharing the negative wire of the speaker or grounding speaker wires to the metal body of the car can cause this unit to fail. • After installation, check that the brake lamps, winkers, and wipers work properly. CENTER UNIT (CD receiver, etc.) Lead terminal* Power control wire FUSE(30A×2) POWER IN Terminal cover Battery wire* Protective Fuse* 789 30 30 RCA cable* RCA cable ground terminal GND B channel input A channel input 456 23 ID NUMBER TO H/U REMOTE RESET A channel Right speaker A channel Left speaker B channel Right speaker B channel Left speaker ■ Bridged Connections A channel Speaker (Bridged) Battery Ground wire* B channel Speaker (Bridged) ■ LX-Bus connection CENTER UNIT Power control wire 30 30 FUSE(30A×2) POWER IN Master amplifier Extension wire* To Kenwood disc changer/ External optional accessory Control cable (option) "0" 23 23 456 789 ID NUMBER TO H/U 456 78 ID NUMBER REMOTE RESET S-video cable* RCA cable* Set the ID number of the Master amplifier to "0". You can connect up to 7 Slave amplifiers. Assign them ID numbers "1" to "7" and do not duplicate them. 2 CAUTION • Do not connect 2 Master amplifiers to the Center Unit. If done, you cannot control all amplifiers connected to the Center Unit. • The LX AMP and the sensor unit cannot be connected simultaneously. You must connect any of them at a time. NOTE • The total length of S-video cables you can connect is 14 meters (46 ft) maximum. If the cable length exceeds this limit, you cannot control amps from the Center Unit. • If you assign the same ID number to multiple amplifiers, they malfunction when you operate any of them from the Center Unit. • If you assign ID number "8" or "9" to a Slave amplifier, it is not recognized by the Center Unit. 30 30 FUSE(30A×2) POWER IN Slave amplifier 1 456 23 23 789 ID NUMBER TO H/U 78 "1" - "7" 456 ID NUMBER REMOTE RESET Not more than 14m (46 ft) 30 30 FUSE(30A×2) POWER IN Slave amplifier 7 4 English 23 23 456 789 ID NUMBER TO H/U 78 456 "1" - "7" ID NUMBER REMOTE RESET

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

4
English
0
1
2
3
4
5
6
7
8
9
3
0
3
0
FUSE(30A
×
2)
POWER IN
RESET
REMOTE
TO H/U
ID NUMBER
GND
Connection
CENTER UNIT
(CD receiver, etc.)
RCA cable ground
terminal
RCA cable*
Lead terminal*
Bridged Connections
Battery
Ground wire*
Battery wire*
Protective Fuse*
* Commercially available parts
Power control wire
LX-Bus connection
0
1
2
3
4
5
6
7
8
9
30
30
FUSE(30A
×
2)
POWER IN
RESET
REMOTE
TO H/U
ID NUMBER
0
1
2
3
4
5
6
7
8
9
30
30
FUSE(30A
×
2)
POWER IN
RESET
REMOTE
TO H/U
ID NUMBER
0
1
2
3
4
5
6
7
8
9
30
30
FUSE(30A
×
2)
POWER IN
RESET
REMOTE
TO H/U
ID NUMBER
ID NUMBER
0
1
2
3
4
5
6
7
8
9
ID NUMBER
0
1
2
3
4
5
6
7
8
9
ID NUMBER
0
1
2
3
4
5
6
7
8
9
"0"
"1" – "7"
"1" – "7"
S-video cable*
Master amplifier
Slave amplifier 1
CENTER UNIT
To Kenwood disc changer/
External optional accessory
2
WARNING
To prevent fire caused by a short in the wiring,
connect a fusible link or breaker nearby the
battery’s positive terminal.
2
CAUTION
• If sound is not output normally, immediately
turn power off and check connections.
• Be sure to turn the power off before changing
the setting of any switch.
• If the fuse blows, check wires for shorts, then
replace the fuse with one of the same rating.
• Check that no unconnected wires or connectors
are touching the car body. Do not remove
caps from unconnected wires or connectors to
prevent short circuits.
• Connect the speaker wires to appropriate
speaker connectors separately. Sharing the
negative wire of the speaker or grounding
speaker wires to the metal body of the car can
cause this unit to fail.
• After installation, check that the brake lamps,
winkers, and wipers work properly.
RCA cable*
Slave amplifier 7
Extension wire*
Set the ID number of the Master amplifier to "0".
You can connect up to 7 Slave amplifiers. Assign them ID numbers "1"
to "7" and do not duplicate them.
2
CAUTION
Do not connect 2 Master amplifiers to the Center Unit. If done, you
cannot control all amplifiers connected to the Center Unit.
• The LX AMP and the sensor unit cannot be connected
simultaneously. You must connect any of them at a time.
NOTE
• The total length of S-video cables you can connect is 14 meters
(46 ft) maximum. If the cable length exceeds this limit, you cannot
control amps from the Center Unit.
• If you assign the same ID number to multiple amplifiers, they
malfunction when you operate any of them from the Center Unit.
• If you assign ID number "8" or "9" to a Slave amplifier, it is not
recognized by the Center Unit.
Not more than
14m (46 ft)
Control cable
(option)
A channel
Left speaker
A channel
Right speaker
B channel
Right speaker
B channel
Left speaker
A channel
Speaker (Bridged)
B channel
Speaker (Bridged)
A channel
input
B channel
input
Terminal cover
Power control wire