KitchenAid KDRS807SSS Dimension Guide - Page 1
KitchenAid KDRS807SSS - 30 Inch Dual Fuel Range Manual
UPC - 883049027555
View all KitchenAid KDRS807SSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
® 30" Freestanding and Slide-In Dual Fuel Range PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS KDRS807S KDRS807X KDSS907S KDSS907X GAS SUPPLY REQUIREMENTS Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. If local codes permit, a new CSA design-certified, 4 ft - 5 ft (122 152.4 cm) long 1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line. A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator. The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range. It should be in a location that allows ease of opening and closing. ELECTRICAL REQUIREMENTS When a 4-wire or 3-wire, single phase 120/240 volt, 60 Hz, AC only electrical supply is available, a 50amp maximum circuit protection is required. When a 4-wire or 3-wire single phase 120/208 volt 60 Hz, AC only electrical supply is available, a 40-amp maximum circuit protection is required, fused on both sides of the line. A separate circuit is recommended. A time-delay fuse or circuit breaker is recommended. Freestanding Range Slide-in Range 30" (76.2 cm) 5³⁄₄" (14.6 cm) 30 77.6 cm) 36" (91.4 cm) cooktop trim height with leveling legs screwed all the way in* 41³⁄₄" (106 cm) overall height with leveling legs screwed all the way in* 23" (58.4 cm) countertop notch to rear of countertop 35⁵⁄₈" (90.5 cm) height to underside of cooktop edge with leveling legs screwed all the way in* Model/serial number plate (located on the right-hand side oven door trim) 27¼" (69.2 cm) max. from handle to standoff at back of range** Model/serial number plate (located on the right-hand side oven door trim) 27¼" (69.2 cm) max. (27 70.3 cm] on model KDSS907XSP) from handle to standoff at back of range** 30" (76.2 cm) *Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs. **When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm) countertop; front of oven door protrudes 1" (2.5 cm) beyond 24" (61 cm) base cabinet. *Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs. **When installed in a 24" (61.0 cm) base cabinet with 25" (63.5 cm) countertop; front of oven door protrudes 1³⁄₄" (4.4 cm) (2 5.5 cm] on models KDRS807XSP and KDSS907XSP) beyond 24" (61.0 cm) base cabinet. †®TEFLON is a registered trademark of E.I. Du Pont Nemours and Company. SLIDE-IN COUNTERTOP PREPARATION 30" (76.2 cm) 30 ¾" (78.1 cm) The cooktop sides of the slide-in range fit over the cutout edge of your countertop. ³⁄₈" If you have a square finish (flat) countertop and the (1.0 cm) opening width is 30" (76.2 cm), no countertop preparation is required. Formed front-edged countertops must have molded edge shaved flat ³⁄₈" (1.0 cm) from each front corner of opening. Tile countertops may need trim cut back ³⁄₈" (1.0 cm) from each front corner and/or rounded edge flattened. If countertop opening width is greater than 30" (76.2 cm), adjust the ³⁄₈" (1.0 cm) dimension. Countertop must be level. Place level on countertop, first side to side; then front to back. If countertop is not level, range will not be level. Range must be level for satisfactory baking conditions. INSTALLATION CLEARANCES Freestanding Ranges 18" (45.7 cm) upper cabinet to countertop 13" (33 cm) upper cabinet depth 30" (76.2 cm) min. opening width 30" (76.2 cm) min. opening width For minimum clearance to top of the cooktop, see NOTE. 5" (12.7 cm) min. clearance from both sides of the range to the side wall or other combustible material. 8" (20.3 cm) This shaded area 8" recommended (20.3 cm) for installation of outlet or junction box. 7" (17.8 cm) 4¹⁄₂" (11.4 cm) This shaded area recommended for installation of rigid gas pipe. 4¹⁄₂" (11.4 cm) 1¹⁄₂" (3.8 cm) Available area for gas and electric installation. Cabinet door or hinge should not extend into the cutout. Slide-In Ranges 13" (33 cm) max. upper cabinet depth 30" (76.2 cm) min. opening width For minimum clearance to top of the cooktop, see NOTE. 18" (45.7 cm) upper cabinet to countertop ³⁄₄" (1.9 cm) radius both corners 30" (76.2 cm) min. opening width 22 58.3 cm) opening depth 5" (12.7 cm) min. clearance from both sides of the range to the side wall or other combustible material. 6" (15.2 cm) This shaded area 6" recommended (15.2 cm) for installation of outlet or junction box. 7" (17.8 cm) 4¹⁄₂" (11.4 cm) This shaded area recommended for installation of rigid gas pipe. 4¹⁄₂" (11.4 cm) 1¹⁄₂" (3.8 cm) Available area for gas and electric installation. Cabinet door or hinge should not extend into the cutout. NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet. If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface. Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Ref. W10246120C 1/28/11