Electrical Shock Hazard
View all KitchenAid KUDC10FXBL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
WARNING Connect wires black to black and white to white, using UL Listed/ CSA Approved twist-on wire connectors (included with power supply cord kit). Electrical Shock Hazard Electrically ground dishwasher. Connect ground wire to green ground connector in terminal box. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. If needed, see website for animated representation of this step. Visit www.kitchenaid.com/electrical under FAQ tab. Remove the ground connector screw and place through the ring terminal of the green ground wire. Reattach and tighten the ground connector screw. Tighten strain relief screws to secure cord. NOTE: Do not pre-twist stranded wire. Twist on wire connector. Gently tug on wires to be sure both are secured. Place wires inside terminal box. Insert tabs on left side of cover. Make sure wires are tucked inside box. Close cover ensuring wires are not pinched. Use ¹⁄₄" hex-head socket, nut driver or Torx® T20® screwdriver and previously removed screw to secure cover. NOTE: Do not plug into outlet until instructed to do so. 13