Syntax in PCL The T-parameter must always be entered. No other parameters are specified with MaxiCode. T-parameter: Identifier for MaxiCode 24800T MaxiCode is initiated by the sequence: (s24800T Additional parameters are not necessary in this sequence; apart from that, the same rules apply as those used for other barcodes. The data following this sequence are interpreted and coded as useful data for the MaxiCode. The subsequent escape sequence terminates the data. The data are divided into primary and secondary information and must appear in that order in the data. The primary information should contain information concerning the shipment. The secondary information should contain information for purposes of processing between consignor and consignee. Other data received from your carrier firm, which often provides more precise guidelines for its customers, which are then also specially tailored for your application. Primary information The primary information is divided into six parts which must also appear in the 48