LG 60PA6550 Owners Manual - Page 45

RS-232C configurations

Page 45 highlights

EXTERNAL CONTROL DEVICE SETUP 5 RS-232C configurations 7-Wire Configuration (Serial female-female NULL modem cable) PC TV RXD 2 3 TXD TXD 3 2 RXD GND 5 5 GND DTR 4 6 DSR DSR 6 4 DTR RTS 7 8 CTS CTS 8 7 RTS D-Sub 9 D-Sub 9 3-Wire Configurations(Not standard) PC TV RXD 2 3 TXD 3 2 GND 5 5 DTR 4 6 DSR 6 4 RTS 7 8 CTS 8 7 D-Sub 9 D-Sub 9 TXD RXD GND DSR DTR CTS RTS Set ID Set ID number. X OPTION • Language • Caption : Off • ISM Method : Normal • Pointer • Balloon Help On • Initial Setting • Set ID : 1 ? 1 Press SETTINGS to access the main menu. 2 Press the Navigation buttons to scroll to SETUP and press OK. 3 Press the Navigation buttons to scroll to option and press OK. 4 Press the Navigation buttons to scroll to Set ID and press OK. 5 Scroll left or right to select a set ID number and select close. The adjustment range is 1-99. 6 When you are finished, press EXIT. ...... *Real data mapping 0 : Step 0 A : Step 10 (SET ID 10) F : Step 15 (SET ID 15) 10 : Step 16 (SET ID 16) 63 : Step 99 (SET ID 99) 64 : Step 100 ... ENEGNLGISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

5
ENG
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
RS-232C configurations
7-Wire Configuration
(Serial female-female NULL modem cable)
PC
TV
RXD
2
3
TXD
TXD
3
2
RXD
GND
5
5
GND
DTR
4
6
DSR
DSR
6
4
DTR
RTS
7
8
CTS
CTS
8
7
RTS
D-Sub 9
D-Sub 9
3-Wire Configurations(Not standard)
PC
TV
RXD
2
3
TXD
TXD
3
2
RXD
GND
5
5
GND
DTR
4
6
DSR
DSR
6
4
DTR
RTS
7
8
CTS
CTS
8
7
RTS
D-Sub 9
D-Sub 9
Set ID
Set ID number.
?
• Language
• Caption
: Off
• ISM Method
: Normal
• Pointer
• Balloon Help
: On
• Initial Setting
• Set ID
:1
OPTION
X
1
Press
SETTINGS
to access the main menu.
2
Press the Navigation buttons to scroll to
SETUP
and press
OK
.
3
Press the Navigation buttons to scroll to
OPTION
and press
OK
.
4
Press the Navigation buttons to scroll to
Set ID
and press
OK
.
5
Scroll left or right to select a set ID number and
select
CLOSE
. The adjustment range is 1-99.
6
When you are finished, press
EXIT
.
*Real data mapping
0 : Step 0
A : Step 10 (SET ID 10)
F : Step 15 (SET ID 15)
10 : Step 16 (SET ID 16)
63 : Step 99 (SET ID 99)
64 : Step 100