Specification Heat Pump(208/230V, 60Hz) HP(Equivalent horsepower) Model Name Combination Unit Independent Unit Capacity Cooling Heating Input Casing Color Heat Exchanger Compressor Fan Cooling Heating Type Piston Displacement Number of Revolution Motor Output x Number Starting Method Oil Type Oil Charge Type Motor Output x Number Air Flow Rate(High) Drive Discharge Pipe Connctions Liquid Pipes Gas Pipes Dimensions (WxHxD) Net Weight Transmission Cable Refigerant Refigerant name Control Power Supply kW kcal/h Btu/h kW kcal/h Btu/h kW kW cm3/rev R.P.M W cc W CMM cfm Side / Top mm(inch) mm(inch) mm inch kg lbs mm2 Ø, V, Hz 34 ARUN330BT2 ARUN115BT2 ARUN115BT2 ARUN096BT2 95.2 81,900 324,800 107.1 92,100 365,400 29.40 31.00 Warm Gray Gold fin DC Scroll (38.3+59.8)*3 (3,600+3,500)x3 (4,130+5,280)x3 Direct On Line FVC68D(PVE) 5600*3 Propeller fan 350 x 6 570 20,100 DC INVERTER TOP 19.05(3/4) 34.9(1 3/8) (1280x1607x730)*2 (50.4x63.3x28.7)*2 285+285+285 628+628+628 CVV-SB 1.25x2C R410A EEV 3, 208/230, 60 Notes: 1. Capacities are based on the following conditions: Cooling * Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB * Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB * Interconnecting Piping Length 7.5m(24.6ft) * Level Difference of Zero Heating * Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB * Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB * Interconnecting Piping Length 7.5m(24.6ft) * Level Difference of Zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. EEV : Electronic Expansion Valve 36 ARUN350BT2 ARUN115BT2 ARUN115BT2 ARUN115BT2 100.8 86,700 343,900 113.4 97,500 386,900 32.40 33.30 Warm Gray Gold fin DC Scroll (38.3+59.8)*3 (3,600+3,500)x3 (4,130+5,280)x3 Direct On Line FVC68D(PVE) 5600*3 Propeller fan 350 x 6 570 20,100 DC INVERTER TOP 19.05(3/4) 41.3(1 5/8) (1280x1607x730)*2 (50.4x63.3x28.7)*2 285+285+285 628+628+628 CVV-SB 1.25x2C R410A EEV 3, 208/230, 60 Conversion Formula kcal/h= kW x 860 Btu/h = kW x 3412 cfm = m3/min x 35.3 l/s = CMM x 1000/60 Copyright ©2009 LG Electronics. Inc. All right reserved. Only for training and service purposes - 12 - LGE Internal Use Only

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

Specification
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
- 12 -
Notes:
1. Capacities are based on the following conditions:
Cooling * Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
* Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
* Interconnecting Piping Length 7.5m(24.6ft)
* Level Difference of Zero
Heating * Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
* Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
* Interconnecting Piping Length 7.5m(24.6ft)
* Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
HP(Equivalent horsepower)
Model Name
Combination Unit
Independent Unit
Capacity
Cooling
kW
kcal/h
Btu/h
Heating
kW
kcal/h
Btu/h
Input
Cooling
kW
Heating
kW
Casing Color
Heat Exchanger
Compressor
Type
Piston Displacement
cm
3
/rev
Number of Revolution
R.P.M
Motor Output x Number
W
Starting Method
Oil Type
Oil Charge
cc
Fan
Type
Motor Output x Number
W
Air Flow Rate(High)
CMM
cfm
Drive
Discharge
Side / Top
Pipe Connctions
Liquid Pipes
mm(inch)
Gas Pipes
mm(inch)
Dimensions (WxHxD)
mm
inch
Net Weight
kg
lbs
Transmission Cable
mm
2
Refigerant
Refigerant name
Control
Power Supply
Ø, V, Hz
34
36
ARUN330BT2
ARUN350BT2
ARUN115BT2
ARUN115BT2
ARUN115BT2
ARUN115BT2
ARUN096BT2
ARUN115BT2
95.2
100.8
81,900
86,700
324,800
343,900
107.1
113.4
92,100
97,500
365,400
386,900
29.40
32.40
31.00
33.30
Warm Gray
Warm Gray
Gold fin
Gold fin
DC Scroll
DC Scroll
(38.3+59.8)*3
(38.3+59.8)*3
(3,600+3,500)x3
(3,600+3,500)x3
(4,130+5,280)x3
(4,130+5,280)x3
Direct On Line
Direct On Line
FVC68D(PVE)
FVC68D(PVE)
5600*3
5600*3
Propeller fan
Propeller fan
350 x 6
350 x 6
570
570
20,100
20,100
DC INVERTER
DC INVERTER
TOP
TOP
19.05(3/4)
19.05(3/4)
34.9(1 3/8)
41.3(1 5/8)
(1280x1607x730)*2
(1280x1607x730)*2
(50.4x63.3x28.7)*2
(50.4x63.3x28.7)*2
285+285+285
285+285+285
628+628+628
628+628+628
CVV-SB 1.25x2C
CVV-SB 1.25x2C
R410A
R410A
EEV
EEV
3, 208/230, 60
3, 208/230, 60
Heat Pump(208/230V, 60Hz)
Conversion Formula
kcal/h= kW x 860
Btu/h = kW x 3412
cfm = m
3
/min x 35.3
l/s = CMM x 1000/60