LG LCU340CP Service Manual - Page 33
Electronic Parts Troubleshooting Guide
View all LG LCU340CP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Electronic Parts Troubleshooting Guide Trouble 1 The Product doesn't operate at all. Troubleshooting Guide Turn off the main power and wait until LED on outdoor PCB is off Turn on the main power again. Does the Operating LED of indoor unit blink When Operation's ON? Is the Connection between CN-POWER of indoor unit and terminal block? Refer to the self-diagnosis function. Check the connecting state of connector Is the Connection of cable between indoor and Outdoor unit right? Is the voltage of CN-POWER in outdoor PCB ASS'Y about AC220/240V? Check the Fuse of outdoor PCB Ass'y. Check the connecting state of wires Check the diagram wiring on the control panel Check the main power. Check the Auto Addressing Work Confirm Auto Addresssing work method Replace the PCB Ass'y * The product's operation starts at three minutes after main power turning on Service Manual 33