LG LP1420BHR Owners Manual - Page 15
Drain Hose Installation for Heating On Some Models, CAUTION
View all LG LP1420BHR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
ENGLISH INSTALLATION 15 Drain Hose Installation for Heating (On Some Models) CAUTION • If you use the Heat mode, you must install the drain hose. If only the Cool mode is used, the drain hose is not needed. • If the outside temperature is at or near freezing 32 °F (0 °C) follow the indoor drainage instructions. • When the weather is above freezing, the unit can be set up to drain to the outside. Make sure the outlet of the hose is aimed away from nearby surfaces that could be stained or damaged by the draining water. Indoor Drainage 1. To attach the drain hose, insert the connector into the pump drain port at the back of the unit until it snaps into place. 2. Place the other end of the drain hose in a bucket that holds at least 28 ounces. Remember to check and empty the bucket frequently to avoid overflows. 3. To detach the drain hose from the product, push the outer ring of the pump drain port in and pull the connector out. NOTE • Inserting the drain hose into the unit will automatically activate the drain function.