Refrigeration Cycle Diagram • Cooling Only Models INDOOR UNIT OUTDOOR UNIT LIQUID SIDE CAPILLARY TUBE HEAT EXCHANGER (EVAPORATOR) GAS SIDE HEAT EXCHANGER (CONDENSER) COMPRESSOR MODEL 9K, 12K (Cooling Only) Pipe size(Diameter:ø) Gas Liquid 1/2" 1/4" Piping length Rated Max 7.62m(25ft) 15m(50ft) Elevation Rated Max 5m(16ft) 7m(23ft) For installation over rated, *a proper quantity of refrigerant should be added for each meter. a proper quantity of refrigerant 9K, 12K 20g Ex) 9K: When installed at a distance of 15m, 148g of refrigerant should be added. (15-7.62) x 20g = 148g -9-
Refrigeration Cycle Diagram
-9-
For installation over rated, *a proper quantity of refr
iger
ant
should be added for each meter.
Ex) 9K: When installed at a distance of 15m, 148g of
refrigerant should be added.
(15-7.62) x 20g = 148g