LG M3203C-BA User Guide - Page 57
Tile H PositionCommand : d e, Transmission, Acknowledgement
View all LG M3203C-BA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
L L RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 21. Tile H Position(Command : d e) To set the Horizontal position. Transmission [d][e][][Set ID][][Data][x] Data Min : 00H ~ Max : 64H • Refer to 'Real data mapping' page A8. Acknowledgement [e][][Set ID][][OK/NG][Data][x] 22. Tile V Position(Command : d f) To set the Vertical position. Transmission [d][f][][Set ID][][Data][x] Data Min : 00H ~ Max : 64H • Refer to 'Real data mapping' page A8. Acknowledgement [f][][Set ID][][OK/NG][Data][x] A15
Controlling the Multiple Product
RS-232C
A15
21. Tile H Position(Command : d e)
To set the Horizontal position.
Transmission
[d][e][][Set ID][][Data][x]
Data
Min : 00H ~ Max : 64H
•
Refer to ‘Real data mapping’ page A8.
Acknowledgement
[e][][Set ID][][OK/NG][Data][x]
22. Tile V Position(Command : d f)
To set the Vertical position.
Transmission
[d][f][][Set ID][][Data][x]
Data
Min : 00H ~ Max : 64H
•
Refer to ‘Real data mapping’ page A8.
Acknowledgement
[f][][Set ID][][OK/NG][Data][x]
Transmission / Receiving Protocol
▲
▲