LG M5203CCBA Owners Manual - Page 68
Power Indicator Command : f o, H Position Command : f q, Power savingCommand : f
View all LG M5203CCBA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
L L RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 46. Power saving(Command : f I) To set the Power saving mode. Transmission [f][I][][Set ID][][Data][Cr] Data 0 : Off 1: (static level 1) 2: (static level 2) 3: (static level 3) Acknowledgement [I][][Set ID][][OK/NG][Data][x] 47. Power Indicator (Command : f o) To set the LED for Power Indicator Transmission [f][o][][Set ID][][Data][Cr] Data 0 : Off 1: On Acknowledgement [o][][Set ID][][OK/NG][Data][x] 48. H Position (Command : f q) To set the Horizontal position Transmission [f][q][][Set ID][][Data][Cr] * The data range is from 00 to 64(in Hex) • Refer to 'Real data mapping' page A 8. Acknowledgement [q][][Set ID][][OK/NG][Data][x] A28 L
Controlling the Multiple Product
RS-232C
A28
46. Power saving(Command : f I)
To set the Power saving mode.
Transmission
[f][I][][Set ID][][Data][Cr]
Data 0 : Off
1: (static level 1)
2: (static level 2)
3: (static level 3)
Acknowledgement
[I][][Set ID][][OK/NG][Data][x]
Transmission / Receiving Protocol
▲
47. Power Indicator (Command : f o)
To set the LED for Power Indicator
Transmission
[f][o][][Set ID][][Data][Cr]
Data 0 : Off
1: On
Acknowledgement
[o][][Set ID][][OK/NG][Data][x]
▲
48. H Position (Command : f q)
To set the Horizontal position
Transmission
[f][q][][Set ID][][Data][Cr]
* The data range is from 00 to 64(in Hex)
•
Refer to ‘Real data mapping’ page A 8.
Acknowledgement
[q][][Set ID][][OK/NG][Data][x]
▲