LG MHEC1737D INSTALLATION - Page 9
Step 3: Prepare the Venting Blower
View all LG MHEC1737D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
us_main.book.book Page 9 Thursday, November 25, 2021 10:15 AM ENGLISH 6 ft 2 ft 1/4" x 10" 90° elbow a (1ea) Wall cap b(1ea) Straight duct (8 ft) Total length For 6" round systems 6 ft = 25 ft = 40 ft = 8 ft = 73 ft 2 ft Transition (1ea) 90°elbows b (2ea) Wall cap c (1ea) Straight duct (8 ft) Total length = 5 ft = 20 ft = 40 ft = 8 ft = 73 ft INSTALLATION 9 the front, unplug the range before covering the cooktop to prevent risk of fire and damage if the knobs are accidentally activated while installing the OTR. a Blanket, cardboard or other covering NOTE • If you have a free-standing range, disconnect it, move it onto a piece of cardboard or hardboard and pull it away from the wall, so that you can get closer to the upper cabinet and back wall for easier measuring and drilling. 3 Remove the mounting plate screws a from the mounting plate b as shown and discard. Step 3: Prepare the Venting Blower Your microwave oven is shipped with the blower assembled for room venting. You need to adjust the blower if you want wall-venting or roof-venting installation. WARNING • Electric shock hazard! Unplug unit before working on it. • Do not pull or stretch the blower wiring. Pulling and stretching the blower wiring could result in electric shock. • To avoid risk of property damage, unplug the microwave oven or disconnect the power at the source by removing the fuse or throwing the circuit breaker. • To avoid risk of personal injury, wear protective gloves when handling the mounting plate. Installation 1 Remove any shipping materials and parts from inside the microwave oven. Set them aside for later use. 2 Cover the countertop or cooktop with a thick, protective covering to protect it from damage and dirt. If your range has cooktop controls in 4 This plate will be used as the rear mounting plate. (It will be used to locate and mark the mounting holes on the rear wall.) 5 Locate the exhaust adapter, grease filters and hardware packet. 6 At this point, remove any adhesive tape (if there is any), on the exhaust adapter, the grease filters and the power supply cord. Room-Venting (Recirculating) Installation This oven is shipped assembled for room-venting. Wall-Venting Installation 1 Remove one cover plate mounting screw a and the cover plate b. Remove one or several blower plate mounting screw(s) c and the blower plate d. Remove the cover plate e