Lenovo NetVista A40p Hardware Maintenance Manual (HMM) for NetVista 2271, 6840 - Page 69

Fast SCSI Adapter

Page 69 highlights

POST Error Code FRU/Action 604 And able to run diagnostics 1. Run Setup and verify diskette configuration settings 2. Diskette Drive A/B 3. Diskette Drive Cable 4. System Board 5. Riser card 605 POST cannot unlock the diskette drive 1. Diskette Drive 2. Diskette Drive Cable 3. System Board 4. Riser card 662 1. Diskette drive configuration error or wrong diskette drive type. Run Setup Configuration 6XX Not listed above 1. Diskette Drive 2. System Board 3. Riser card 4. External Drive Adapter 5. Diskette Drive Cable 6. Power Supply 762 Math coprocessor configuration error 1. Run Setup 2. Processor 3. System Board 7XX Not listed above 1. Processor 2. System Board 962 Parallel port configuration error 1. Run Configuration 2. Parallel Adapter (if installed) 3. System Board 9XX 1. Printer 2. System Board 1047 1. 16-Bit AT™ Fast SCSI Adapter 107X Check SCSI terminator installation 1. Check SCSI terminator installation 2. SCSI Cable 3. SCSI Terminator 4. SCSI Device 5. SCSI Adapter 1101 1. Run diagnostics Serial connector error, possible system board failure 1101, 1102, 1106, 1108, 1109 1. System Board 2. Any Serial Device 1107 1. Communications Cable 2. System Board Chapter 6. Symptom-to-FRU Index 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

POST Error Code
FRU/Action
604
And able to run diagnostics
1.
Run Setup and verify diskette
configuration settings
2.
Diskette Drive A/B
3.
Diskette Drive Cable
4.
System Board
5.
Riser card
605
POST cannot unlock the diskette drive
1.
Diskette Drive
2.
Diskette Drive Cable
3.
System Board
4.
Riser card
662
1.
Diskette drive configuration error or
wrong diskette drive type. Run Setup
Configuration
6XX
Not listed above
1.
Diskette Drive
2.
System Board
3.
Riser card
4.
External Drive Adapter
5.
Diskette Drive Cable
6.
Power Supply
762
Math coprocessor configuration error
1.
Run Setup
2.
Processor
3.
System Board
7XX
Not listed above
1.
Processor
2.
System Board
962
Parallel port configuration error
1.
Run Configuration
2.
Parallel Adapter (if installed)
3.
System Board
9XX
1.
Printer
2.
System Board
1047
1.
16-Bit AT
Fast SCSI Adapter
107X
Check SCSI terminator installation
1.
Check SCSI terminator installation
2.
SCSI Cable
3.
SCSI Terminator
4.
SCSI Device
5.
SCSI Adapter
1101
Serial connector error, possible system board
failure
1.
Run diagnostics
1101, 1102, 1106, 1108, 1109
1.
System Board
2.
Any Serial Device
1107
1.
Communications Cable
2.
System Board
Chapter 6. Symptom-to-FRU Index