Lexmark 23S0300 User's Guide - Page 19
Using the operator panels, Insufficient collation area, Load media
View all Lexmark 23S0300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Using the operator panels Insufficient collation area Light sequence: Error-On Secondary light sequence: Press twice quickly to see the secondary light sequence. Ready / Data-Blinks three times Message: Printer memory does not have the free space necessary to collate print job. May occur due to one of the errors listed below: • Printer memory is full. • A page is too complex to print. • Memory is insufficient to save what is in the print buffer. Primary light sequence Secondary light sequence Solution: Turn printer off and back on to try printing the page again. If not successful: • Press to clear message and continue processing the job (some print data may be lost). To avoid this error in the future: • Reduce complexity of the page by reducing the amount of text or graphics. • Set Page Protect to On in the Local Printer Setup Utility (see Software and Documentation CD). Load media Light sequence: Error-Blinking Secondary light sequence: Press twice quickly to see the secondary light sequence. Ready / Data-Blinks once Message: Printer is out of media, or media did not feed properly. Primary light sequence Solution: • Load media into Tray 1 or priority feeder and press to resume. • Ensure media is loaded correctly in Tray 1 or priority feeder. • Press to cancel print job. Secondary light sequence Overview of the Lexmark E120 operator panel 19