Lexmark Forms Printer 2590 Technical Reference - Page 60

Barcode Length, Table 2-19, Barcode Space Width Adjustment

Page 60 highlights

Draft document 2-40 Bar Code Adjustment Values are: Table 2-19: Barcode Space Width Adjustment s Decimal Hexadecimal -3 253 FD -2 254 FE -1 255 FF 0 0 00 (default) 1 1 01 2 2 02 3 3 03 Note: Undefined s value is handled as default value. Note : Bar/Space number of one digit (Interleaved 2 of 5 : one pair digit) Barcode Type NW-7 EAN/UPC-A CODE 39 Interleaved 2 of 5 CODE 128 BAR 4 2 5 5 3 SPACE 3 2 4 + 1 Gap 5 3 "s" value affects barcode printing width. If barcode printing area reaches to the right or left margin, the printer ignores this command. Barcode Length The variables v1 and v2 control the bar length. V1 specifies lower byte. V2 specifies upper byte. Bar length is controlled by multiple value of a unit of 1/2160 inch. Values for V1, V2 are: minimum values Table 2-20: Barcode Length Model 24 wire (259X) 9 wire (248X) V1, V2 value Decimal Hexadecimal 288 120 270 10E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

Bar Code
2-40
Draft document
Adjustment Values are:
Note : Bar/Space number of one digit (Interleaved 2 of 5 : one pair digit)
"s" value affects barcode printing width. If barcode printing area reaches to the right
or left margin, the printer ignores this command.
Barcode Length
The variables v1 and v2 control the bar length. V1 specifies lower byte.
V2 specifies
upper byte.
Bar length is controlled by multiple value of a unit of 1/2160 inch.
Values for V1, V2 are:
Table 2-19:
Barcode Space Width Adjustment
s
Decimal
Hexadecimal
-3
253
FD
-2
254
FE
-1
255
FF
0
0
00 (default)
1
1
01
2
2
02
3
3
03
Note:
Undefined s value is handled as default value.
Barcode Type
BAR
SPACE
NW-7
4
3
EAN/UPC-A
2
2
CODE 39
5
4 + 1 Gap
Interleaved 2 of 5
5
5
CODE 128
3
3
Table 2-20:
Barcode Length
V1, V2 value
Model
Decimal
Hexadecimal
minimum values
24 wire (259X)
288
120
9 wire (248X)
270
10E