LA412DC Current consumption by control board feature 12v (LA412DC) configurations. Add up current draw by feature and accessory to determine total current draw. System voltage 12v Main board with no radios learned (mA) 4.2 One or more LiftMaster® transmitters learned (mA) +1.5 MyQ® device or wireless dual gate learned (mA) +3.9 Expansion board (mA) +18.5 Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board) (mA) +6.6 LA412DC Single gate solar cycles per day Battery current draw (mA) 6 25 10W Solar Panel 30 50 100 6 25 20W Solar Panel 30 100 200 6 30W Solar Panel Note: 30W would be 25 (3) 10W 12V panels in 30 parallel 100 200 Zone 1 (6 Hrs Sunlight/Day) 7AH batteries 33AH battery 100 100 100 100 100 100 91 98 43 49 100 100 100 100 100 100 100 100 75 100 100 100 100 100 100 100 100 100 100 100 Zone 2 (4 Hrs Sunlight/Day) 7AH batteries 33AH battery 82 86 63 67 58 63 40 44 3 5 100 100 100 100 100 100 77 95 #NUM! 7 100 100 100 100 100 100 100 100 51 91 Zone 3 (2 Hrs Sunlight/Day) 7AH batteries 33AH battery 32 34 17 19 14 15 1 2 #NUM! #NUM! 73 82 55 64 51 59 #NUM! #NUM! 3 #NUM! 100 100 90 100 85 100 22 #NUM! 39 #NUM! Dual gate solar cycles per day * Zone 1 (6 Hrs Sunlight/Day) Zone 2 (4 Hrs Sunlight/Day) Zone 3 (2 Hrs Sunlight/Day) 7AH batteries 33AH battery 7AH batteries 33AH battery 7AH batteries 33AH battery 59 62 35 37 14 15 50 53 27 29 7 8 48 51 25 27 6 7 39 42 17 19 1 1 19 21 1 2 #NUM! #NUM! 100 100 76 85 31 35 100 100 67 76 24 27 100 100 65 73 22 25 78 92 33 41 #NUM! 1 32 44 #NUM! 3 #NUM! #NUM! 100 100 100 100 47 57 100 100 100 100 39 48 100 100 100 100 37 46 100 100 66 86 9 17 83 100 22 39 #NUM! #NUM! The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature effects on batteries in the given regions. Local geography and weather conditions may require additional solar panels. Solar optimized or wireless accessories are recommended in order to minimize power draw, as added accessories draw power and affect the daily cycle rate. For full details please reference the manual. 3 not available 2 3 1 2 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

LA412DC
The map and daily cycle rate
shown are approximations based
upon the average solar radiation
and the temperature effects on
batteries in the given regions.
Local geography and weather
conditions may require additional
solar panels. Solar optimized
or wireless accessories are
recommended in order to minimize
power draw, as added accessories
draw power and affect the daily
cycle rate. For full details please
reference the manual.
1
not available
3
2
1
2
3
Current consumption by control board feature 12v (LA412DC) configurations. Add up
current draw by feature and accessory to determine total current draw.
System voltage
12v
Main board with no radios learned (mA)
4.2
One or more LiftMaster
®
transmitters learned (mA)
+1.5
MyQ
®
device or wireless dual gate learned (mA)
+3.9
Expansion board (mA)
+18.5
Per loop detector LOOPDETLM (up to 3 loop detectors
can be plugged in to the expansion board) (mA)
+6.6
*
7AH
batteries
33AH
battery
7AH
batteries
33AH
battery
7AH
batteries
33AH
battery
7AH
batteries
33AH
battery
7AH
batteries
33AH
battery
7AH
batteries
33AH
battery
6
100
100
82
86
32
34
59
62
35
37
14
15
25
100
100
63
67
17
19
50
53
27
29
7
8
30
100
100
58
63
14
15
48
51
25
27
6
7
50
91
98
40
44
1
2
39
42
17
19
1
1
100
43
49
3
5
#NUM!
#NUM!
19
21
1
2
#NUM!
#NUM!
6
100
100
100
100
73
82
100
100
76
85
31
35
25
100
100
100
100
55
64
100
100
67
76
24
27
30
100
100
100
100
51
59
100
100
65
73
22
25
100
100
100
77
95
#NUM!
3
78
92
33
41
#NUM!
1
200
75
100
#NUM!
7
#NUM!
#NUM!
32
44
#NUM!
3
#NUM!
#NUM!
6
100
100
100
100
100
100
100
100
100
100
47
57
25
100
100
100
100
90
100
100
100
100
100
39
48
30
100
100
100
100
85
100
100
100
100
100
37
46
100
100
100
100
100
22
39
100
100
66
86
9
17
200
100
100
51
91
#NUM!
#NUM!
83
100
22
39
#NUM!
#NUM!
Zone 3
(2 Hrs Sunlight/Day)
Zone 1
(6 Hrs Sunlight/Day)
Zone 2
(4 Hrs Sunlight/Day)
LA412DC
Single gate solar cycles per day
Dual gate solar cycles per day
Zone 3
(2 Hrs Sunlight/Day)
10W Solar Panel
20W Solar Panel
30W Solar Panel
Note: 30W would be
(3) 10W 12V panels in
parallel
Battery
current
draw (mA)
Zone 1
(6 Hrs Sunlight/Day)
Zone 2
(4 Hrs Sunlight/Day)