LiftMaster H J LOW PROFILE ELEC.BOX Manual - Page 15

Three Phase

Page 15 highlights

THREE PHASE WIRING DIAGRAM 1742-3 WARNING Always Disconnect Power Whenever Installing or Servicing the Door Operator. RADIO RECEIVER R1 R2 R3 AUX.TERMINAL BLOCK FOR RADIO C NO AUX.OPEN L/S NC ORANGE YELLOW RED RED YELLOW PURPLE ORANGE OPEN LIMIT SWITCHES OPEN L/S NC C ORANGE ORANGE PURPLE RED YELLOW GREY PURPLE CLOSE A1 A2 13 14 5 6 3 4 1 2 PURPLE PURPLE PURPLE BLACK BLACK WHITE ORANGE ORANGE A1 A2 13 14 5 6 3 4 1 2 OPEN ORANGE YELLOW BLACK BLACK BLACK R1 RELAY ( 3/4 HP & BELOW ) BROWN RED PURPLE PURPLE C NO NC ORANGE ORANGE RED ( 1 HP & ABOVE ) ( 3/4 HP & BELOW ) INTERLOCK ( OPTIONAL ) YELLOW GREY PURPLE TO TERMINAL #2 PURPLE PURPLE TO TERMINAL #3 TIMER ( OPTIONAL ) GREY GREY C NC SAFETY L/S CLOSE LIMIT SWITCHES PURPLE NC CLOSE L/S C PURPLE BLACK BROWN LOAD 24VAC YELLOW BLACK XFMR **LINE WIRE NUT ( 3/4 HP & BELOW) *SEE NOTE: T1 L1 T2 L2 T3 L3 BROWN 96 BROWN 95 OVERLOAD ( 1 HP & ABOVE ONLY ) OVERLOAD (UP TO 3/4 HP) 230V. BRAKE SOLENOID ( WHEN REQUIRED ) RED ORANGE GREY ORANGE PURPLE PURPLE RED ORANGE YELLOW ORANGE BROWN BROWN ORANGE YELLOW YELLOW GREY BLACK BLACK BLACK BROWN BROWN BL-BK BL-BK BRAKE ( WHEN REQ'D ) TO MOTOR GY BR P BR Y BL-BK 1 74 J 2 85 3 96 J BL-BK 230V. CONNECTION GY BR P BR Y 17 28 39 BL-BK 4J 5 6J BL-BK 460V. CONNECTION GY BR P BR Y BL-BK 1 J 2 3 J BL-BK 575V. CONNECTION OVERLOAD 575V. BRAKE SOLENOID ( WHEN REQUIRED ) OVERLOAD (UP TO 3/4 HP) 230V. BRAKE SOLENOID ( WHEN REQUIRED ) 1 2 3 4 5 7 10 L1 L2 L3 OPEN CLOSE STOP EXT. INTLK. TO OPEN AND CLOSE L1 L2 L3 **3 PHASE GROUND POWER IN SAFETY EDGE * - Shipped from Factory CLOSE CONTROL WIRING OPTIONS *C2 WIRING - Constant Presssure to Close RED WIRE ON TERMINAL #2 (Shipped from Factory) B2 WIRING - Momentary Contact to Close MOVE RED WIRE FROM TERMINAL #2 TO TERMINAL #3 ** - Transformer Primary Voltage same as Line Voltage. TO REVERSE MOTOR DIRECTION INTERCHANGE PURPLE & GRAY WIRES. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

THREE PHASE WIRING DIAGRAM
1742-3
C
NO
NC
R1
RELAY
Always Disconnect
Power Whenever
Installing or Servicing
the Door Operator.
INTERCHANGE PURPLE & GRAY WIRES.
TO REVERSE MOTOR DIRECTION
C2 WIRING
-
Constant Presssure to Close
RED WIRE ON TERMINAL #2 (Shipped from Factory)
B2 WIRING
-
Momentary Contact to Close
MOVE RED WIRE FROM TERMINAL #2 TO TERMINAL #3
WARNING
*
BRAKE
( WHEN REQ'D )
YELLOW
( OPTIONAL )
BL-BK
BL-BK
TO MOTOR
PURPLE
GREY
ORANGE
GREY
ORANGE
RED
PURPLE
PURPLE
ORANGE
RED
ORANGE
YELLOW
BROWN
PURPLE
PURPLE
INTERLOCK
RED
ORANGE
ORANGE
RED
ORANGE
ORANGE
3
1
OPEN
A1
5
13
WHITE
PURPLE
PURPLE
YELLOW
RED
GREY
1
A1
13
3
5
BLACK
YELLOW
4
2
A2
6
14
PURPLE
PURPLE
BLACK
2
A2
14
4
6
AUX.TERMINAL
BLOCK FOR RADIO
OPEN
C
L/S
NC
AUX.OPEN
C
L/S
NC
NO
RECEIVER
RADIO
ORANGE
R3
PURPLE
ORANGE
YELLOW
RED
RED
R2
R1
YELLOW
ORANGE
YELLOW
ORANGE
BROWN
YELLOW
GREY
BLACK
WIRE NUT
LOAD
24VAC
YELLOW
BLACK
XFMR
LINE
( OPTIONAL )
SAFETY
PURPLE
TO TERMINAL #3
GREY
GREY
BLACK
BROWN
PURPLE
PURPLE
C
NC
L/S
CLOSE
C
NC
L/S
PURPLE
TO TERMINAL #2
TIMER
PURPLE
BLACK
BLACK
BLACK
BLACK
T1
L1
L2
T2
T3
L3
95
96
OVERLOAD
( 1 HP & ABOVE ONLY )
BROWN
ORANGE
BLACK
( WHEN REQUIRED )
230V. BRAKE SOLENOID
GY
BR
Y
BR
P
460V. CONNECTION
9
3
6
230V. CONNECTION
8
7
1
2
4
5
BL-BK
J
BL-BK
J
BROWN
BROWN
BROWN
( 3/4 HP & BELOW)
BROWN
( 1 HP & ABOVE )
( 3/4 HP & BELOW )
( 3/4 HP & BELOW )
SEE NOTE:
EXT.
INTLK.
AND CLOSE
TO OPEN
SAFETY
STOP
1
OPEN
CLOSE
3
2
4
GROUND
3 PHASE
POWER IN
L1
L1
5
7
10
L2
L3
L2
EDGE
*
CLOSE
LIMIT SWITCHES
OPEN
LIMIT SWITCHES
GY
BR
Y
BR
P
9
3
6
8
7
1
2
4
5
OVERLOAD
(UP TO 3/4 HP)
BL-BK
J
BL-BK
J
( WHEN REQUIRED )
230V. BRAKE SOLENOID
L3
CLOSE
CONTROL
WIRING
OPTIONS
OVERLOAD
(UP TO 3/4 HP)
-
Shipped from Factory
*
CLOSE
PURPLE
ORANGE
**
**
-
Transformer Primary Voltage same as Line Voltage.
**
GY
BR
Y
BR
P
575V. CONNECTION
3
2
1
BL-BK
J
BL-BK
J
( WHEN REQUIRED )
575V. BRAKE SOLENOID
OVERLOAD
15