LiftMaster HS670 HS670 GL BOARD Manual

LiftMaster HS670 Manual

LiftMaster HS670 manual content summary:

  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 1
    GLCONTROLLER BOARD MODEL HS670 HEAVY DUTY HYDRAULIC SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial located on electrical box cover) Installation Date MODEL HS670 IS FOR VEHICULAR PASSAGE GATES ONLY AND IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 2
    operate or maintain the operator, you MUST read and fully understand this manual and follow all safety instructions. • DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician. Safety Installation Information 6 Suggested Entrapment
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 3
    travel. D. BYPASS VALVE Incorporates a handle at side of pump. When positioned downward, it will allow manual operation of the gate. E. RELIEF VALVE Built into pump. Set at 600 p.s.i. for HS670 1HP and 1500 p.s.i. for HS670 2HP. F. VENT CAP When removed, you may add hydraulic oil. Must be on during
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 4
    OPERATOR DIMENSIONS AND HORSEPOWER CHART MODEL HS670 GC • 1 HP Motor Gate Speed - 12"/sec. Maximum Gate Weight - 3000 lbs. Maximum V-Track Gate Width - 80 ft. MODEL HS670 GI • 1 HP Motor Gate Speed - 18"/sec. Maximum Gate Weight - 3000 lbs. Maximum V-Track Gate Width - 80 ft. MODEL HS670
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 5
    vehicles onl.y Pedestrians must use separate entrance MODEL CLASS 1 CLASS 2 CLASS 3 CLASS 4 HS670 GC HS670 GI N/A N/A UL325 ENTRAPMENT PROTECTION REQUIREMENTS GATE OPERATOR ENTRAPMENT PROTECTION UL325 Installation Class Class I & II Slide Gate Operator Primary Type A Secondary Type B1, B2
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 6
    Rollers • Vertical Posts • Photoelectric Sensors • Instructional and Precautionary Signage 4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate. b. All openings of a horizontal slide gate are guarded or screened from the bottom
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 7
    OPERATOR WARNINGS SUGGESTED ENTRAPMENT PROTECTION DEVICE LOCATIONS GATE SYSTEM (COMMERCIAL SLIDE GATE) Sentex Telephone Entry System/Access Control Open Edge Close Edge * 1/4" Or As Required For Loop Wire Width *Refer to loop manufacturer's instructions for detailed installation and loop wiring
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 8
    inside and outside of a vehicular horizontal slide gate. Non-contact sensors such as photo eyes must protect during both open and close gate cycles. • Injuries occur when people put their hands and arms through openings in the grill while the gate is operating. They cannot retract their arm and it
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 9
    . For detailed information on the emergency disconnect system, see instructions provided with it. This is only a suggested layout, the gate opening width plus 3' to 4'. The drive rail must be level and parallel to the gate and operator. 2. Fasten the drive rail securely to the gate and
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 10
    operator Manually open the gate about halfway. Measure and drill holes to mount limit shoes 7. Secure both limit shoes to underside of drive rail. NOTE: It is highly suggested that gate stops be installed to the gate at the fully open and closed positions. See next page for installation instructions
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 11
    Separator Bolt (Use 9/16" Socket) Lock Adjustment Lower Nut (Use 3/4" Wrench) Guide Wheel (provided on operator for use with LiftMaster Drive Rail) Upper Drive Wheel Drive Rail Guide Wheel Lower Drive Wheel Bypass Valve Handle In Automatic Position Rotate 90° (Down) For Manual Operation 11
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 12
    the operator • ANY maintenance to the operator or in the area near the operator MUST power disconnect should be returned to service. visible and clearly labeled. • On a Dual Gate System, each unit . Local codes and conditions must be reviewed for suitability of wire installation. All power
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 13
    Cover Wire Nut Connections (see instructions) Power Wiring Conduit SINGLE PHASE All single phase 115V/230V operators will have the following: • IMPORTANT NOTE: On three phase operators, power connections must be properly phased. If phased incorrectly, the gate operator will run reversed. To correct
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 14
    alignment due to shipping vibration or rough handling. These operators use an internal entrapment protector system. This system consists of the control board, and unsafe operation. NOTE: Motor Learn must be performed in stand alone mode. 1. The operator must remain attached to the gate throughout the
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 15
    the unit will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force. On most operators this will be around the middle of the range. SECONDARY ENTRAPMENT PROTECTION ADJUSTMENTS Terminals 9 & 5 - Obstruction While Opening (Edge
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 16
    to Close Force Adjustment DIP Switch (S2) DIP Switch (S1) Diagnostic LED Connector (J2) Connector SAMS (J5) Relay Drive Troubleshooting LEDs (D6) Terminal Troubleshooting LEDs (D11) Limit LEDs Programming Port (factory use only) Motor Learn Button Connector Aux. Relay Drive (J3, not used) 16
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 17
    SLIDE/SWING This switch (S1-2) selects slide or swing gate operation, in order to optimize gate behavior for specific application. SL = Slide, 1 second delay SW = Swing, 1.5 second delay TTC SW RT SWING GATE S1 ON ON 1 2 34 SAVE TTC SW RT SLIDE GATE gate "in motion" alarm feature. The alarm
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 18
    to reverse the gate to the open limit when activated during the close cycle. The entrapment is not cleared one second. If the master gets no response the operator will operate in a stand alone mode. NOTE: For single HS670 Interrupt Loop HS670 (Gate Conduit) Interrupt Loop 6' COMPLEX OR PARKING
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 19
    Steps 2 and 3 for each remote control that will be used to operate the gate operator. TO ERASE ALL REMOTE CONTROL CODES Press and hold the "learn" button THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 20
    system is that traffic is controlled by two gates installed in tandem, a fast moving gate such as a barrier gate operator and a slower moving more secure or ornamental gate such as a single or pair of slide/swing gate operator. The design of this gate system balances the demands of speed during high
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 21
    Timer. NOTE: Will not override a double entrapment (signalled by the gate stopped and entrapment alarm on). 123 56 789 0# Radio ( use with a loop detector and is primarily used on swing gate operators. This input protects cars by preventing the gate from moving off of the open or close limit when
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 22
    where the user has full view of gate operation. Hard Close Control Input (N.O.) OPEN CLOSE STOP Stop/Reset Control Input (N.C.) OPEN CLOSE STOP Shadow Loop Input (N.O.) All inputs are normally open and momentary, except the stop (N.C.). The following instructions are based upon UL325, and include
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 23
    LiftMaster SEMENT AVERTISSEMENT Failure to adjust and retest the gate operator properly professional. can increase the risk of INJURY or DEATH. 10. SAVE THESE INSTRUCTIONS. ION AVERTISSEMENT DESCRIPTION RPM Sensor (Hall Effect) External Entrapment Protection Systems Gate Caution Signs Manual
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 24
    4 5 6 On No Flash Diagnostic Meaning Normal operation Single entrapment sensed Double entrapment Failed or no RPM sensor (Hall effect) Exceed when Mag Lock relay is activated On when Alarm Relay is activated TROUBLESHOOTING LEDS There are 9 troubleshooting LEDs. LED LED NAME D11 Radio D13
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 25
    TROUBLESHOOTING FAULT POSSIBLE CAUSE FIX OPERATOR FAILS TO RUN 1) No stop control 2) Fault in the operator -12. If operator is in a dual gate configuration, make manual. OPERATOR RUNS SLOW AND/OR TRIPS THE INTERNAL OVERLOAD 1) Low primary (high voltage) power 2) Problem in the motor 3) Problem
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 26
    TROUBLE 1) Operator's manual release is engaged LEARNING THE MOTOR PROGRAMMING CHANGES 1) Check the save switch on switch S1-1 DO NOT EFFECT THE GATE ➤ Make sure that the unit's manual release is not engaged. The unit's manual release, when disengaged, will set off the entrapment sensor if the gate
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 27
    G MECHANICAL TROUBLESHOOTING SYMPTOM UNIT SOUNDS LIKE IT IS WORKING BUT GATE DOES NOT MOVE JERKING GATE MOVEMENT SQUEALING SOUND WHEN GATE MOVES GATE WILL NOT STOP hold the manual override button on valve. If unit works okay, check valve for proper wiring. See page 31. (D) HOSES: Double-check hose
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 28
    TROUBLESHOOTING circuit. 2. Both models have a bypass valve with handle. When this valve is positioned for manual operation, it will redirect the motor's speed is 37 RPM and gate speed of 12"/sec. 3. The drive wheels are: HS670 1HP (1-1/2" w. x 6" dia.) HS670 2HP (2" w. x 6" dia.). Circumference
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 29
    TROUBLESHOOTING use hydraulic oil. 3. DO NOT put pipe dope or teflon tape on any part of hose fittings. 4. DO NOT remove vent cap except to fill tank with hoses, remove power, position bypass valve to manual operation, and press and hold directional valve manual override for about 30 seconds. You will
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 30
    PHASE WIRING DIAGRAM EMMERSON MOTOR CONNECTIONS OVERLOAD (SEE NOTE 6) BALDOR MOTOR CONNECTIONS (LEFT) (RIGHT) NOTES: 1. Transformer primary voltage same as operator line voltage 24V secondary 60VA. 2. Wire color: 120V black, 230V orange. 3. Coil voltage same as line voltage. 4. (B+) and (B-) are
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 31
    DIAGRAM 4 (LEFT) (RIGHT) NOTES: 1. Transformer primary voltage same as operator line voltage 24V secondary 60VA. 2. Wire color: 230V orange, 460V violet. 3. Coil voltage same as line voltage. 4. (B+) and (B-) are 100dB safety alarms. 5. For single button radio function, perform the optional wire
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 32
    COMPLETE ELECTRICAL BOX REPLACEMENT KITS To order a complete electrical box replacement kit, add a Kprefix to the model number of your operator. For example: HS670-100-21 (Operator) = K-HS670-100-21 (Electrical Box Kit) 3 5 7 10 2 13 8 15 6 12 9 9 14 11 1 4 ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 33
    29-19203 80-19011 K75-19104 INDIVIDUAL PARTS AND KITS DESCRIPTION QTY Motor, 1HP 115/230V 1PH 1 Motor, 1HP 230/460V 3PH Motor, 2HP 230/460V 2 Guide Assembly 1 Base Assembly 1 Drive Wheel, 1HP 2 Drive Wheel, 2HP Limit Switch 1 Directional Valve 1 Arm Bushings Kit 1 Operator Cover
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 34
    LIFTMASTER® TWO YEAR LIMITED WARRANTY The Chamberlain service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem parts will be repaired or replaced with new or factory-rebuilt parts OPERATION OR WITH THE SALE OF THIS
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 35
    OPERATOR NOTES 35
  • LiftMaster HS670 | HS670 GL BOARD Manual - Page 36
    AMERICA For installation and service information, call our TOLL FREE number: 1-800-528-2806 www.liftmaster.com When ordering repair parts please supply the following information: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Technical Support Group 6020 Country
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

CONTROLLER BOARD
GL
Serial #
________________________
(located on electrical box cover)
Installation Date __________________
2 YEAR WARRANTY
MODEL HS670 IS FOR VEHICULAR PASSAGE GATES ONLY AND
IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE
MODEL HS670
H
EAVY
D
UTY
H
YDRAULIC
S
LIDE
G
ATE
O
PERATOR