7. Install Hand Chain (Models H and HJ only) Place hand chain around hand chain wheel. Be sure to pass it through both openings in the chain guide. Remove enough links so chain hangs approximately two feet above the floor 8. Mount Chain Keeper / Keyhole Bracket Using suitable hardware mount the chain keeper approximately 4 feet above the floor, near the free hanging chain. Remove disconnect sash chain from bag and place the end through the keyhole in the the chain keeper. Remove excess links if necessary. EMERGENCY MANUAL OPERATION This operator has provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions below for your model operator. Model H These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. To operate the hoist: 1. Pull the disconnect chain (small chain) to engage the hoist mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall. 2. Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain (large chain). 3. The disconnect chain must be released from the chain keeper before the door will operate again electrically. CAUTION TURN OFF POWER TO THE OPERATOR BEFORE MANUALLY OPERATING YOUR DOOR. Chain Keeper (with pad locking provisions) Model J This operator has a floor level disconnect chain to disconnect the door from the door operator. 1. To disengage, pull the chain and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall. Or if emergency egress device is used, pull handle to disengage operator from door. 2. The door may now be pushed up or pulled down manually. Release the disconnect chain to operate the door again electrically. Electrical Interlock with Hoist for Models H and HJ Keyhole Bracket Model HJ This operator includes both, a floor level disconnect chain to disconnect the door from the door operator and and a disconnect chain with manual hoist to electrically disable the electrical controls. 1. Refer to model H instructions for hoist operation. 2. Refer to model J instructions for manual operation. Manual Disconnect for Models J and HJ 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

These operators are equipped with a manual hoist.
An electrical interlock will disable the electrical
controls when the hoist is used. To operate the hoist:
1. Pull the disconnect chain (small chain) to engage
the hoist mechanism. The disconnect chain may be
locked in position by slipping the end through the
keyhole of the chain keeper mounted on the wall.
2. Operate the door in the desired direction by pulling
on one side or the other of the continuous loop hoist
chain (large chain).
3. The disconnect chain must be released from the
chain keeper before the door will operate again
electrically.
5
7.
Install Hand Chain
(Models H and HJ only)
Place hand chain around hand chain wheel.
Be
sure to pass it through both openings in the chain
guide.
Remove enough links so chain hangs
approximately two feet above the floor
EMERGENCY
MANUAL
OPERATION
This operator has provisions for manually operating the door in case of emergency or power failure.
Refer to the
appropriate instructions below for your model operator.
Model
H
Model
J
This operator has a floor level disconnect chain to
disconnect the door from the door operator.
1.
To disengage, pull the chain and secure in the
disengaged position by slipping the end through the
keyhole bracket mounted on the wall.
Or if
emergency egress device is used, pull handle to
disengage operator from door.
2.
The door may now be pushed up or pulled down
manually. Release the disconnect chain to operate
the door again electrically.
Chain Keeper
(with pad locking provisions)
Keyhole Bracket
8.
Mount Chain Keeper / Keyhole Bracket
Using suitable hardware mount the chain keeper
approximately 4 feet above the floor, near the free
hanging chain.
Remove disconnect sash chain
from bag and place the end through the keyhole
in the the chain keeper.
Remove excess links if
necessary.
Model
HJ
This operator includes both, a floor level disconnect
chain to disconnect the door from the door operator
and and a disconnect chain with manual hoist to
electrically disable the electrical controls.
1.
Refer to model H instructions for hoist operation.
2.
Refer to model J instructions for manual operation.
Manual Disconnect for Models J and HJ
Electrical Interlock with Hoist for Models H and HJ
TURN OFF POWER TO THE OPERATOR BEFORE
MANUALLY OPERATING YOUR DOOR.
CAUTION
CAUTION