Makita AD03R1 AD03 AD04 Instruction Manual - Page 2

Specifications, Safety Warnings

Page 2 highlights

ENGLISH (Original instructions) SPECIFICATIONS Model: AD03 AD04 Drilling capacities Steel 10 mm (3/8") Wood 12 mm (1/2") No load speed (RPM) 0 - 1,100 /min Overall length 313 mm - 332 mm (12-3/8" - 13-1/8") Rated voltage D.C. 10.8 V - 12 V max Standard battery cartridge BL1016 / BL1021B / BL1041B Net weight 1.2 - 1.3 kg (2.6 - 2.9 lbs) 1.2 - 1.4 kg (2.7 - 3.0 lbs) • Due to our continuing program of research and development, the specifications herein are subject to change without notice. • Specifications and battery cartridge may differ from country to country. • The weight may differ depending on the attachment(s), including the battery cartridge. The lightest and heaviest combination, according to EPTA-Procedure 01/2014, are shown in the table. SAFETY WARNINGS General power tool safety warnings WARNING: Read all safety warnings, instructions, illustrations and specifications provided with this power tool. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The term "power tool" in the warnings refers to your mains-operated (corded) power tool or BATTERYoperated (cordless) power tool. Work area safety 1. Keep work area clean and well lit. Cluttered or dark areas invite accidents. 2. Do not operate power tools in explosive atmo- spheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes. 3. Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control. Electrical Safety 1. Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock. 2. Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded. 3. Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock. 4. Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock. 5. When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock. 6. If operating a power tool in a damp location is unavoidable, use a ground fault circuit interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of electric shock. 7. Power tools can produce electromagnetic fields (EMF) that are not harmful to the user. However, users of pacemakers and other similar medical devices should contact the maker of their device and/ or doctor for advice before operating this power tool. Personal Safety 1. Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury. 2. Use personal protective equipment. Always wear eye protection. Protective equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries. 3. Prevent unintentional starting. Ensure the switch is in the off-position before connecting to power source and/or BATTERY pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents. 4. Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury. 2 ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

2
ENGLISH
ENGLISH (Original instructions)
SPECIFICATIONS
Model:
AD03
AD04
Drilling capacities
Steel
10 mm (3/8")
Wood
12 mm (1/2")
No load speed (RPM)
0 - 1,100 /min
Overall length
313 mm - 332 mm (12-3/8" - 13-1/8")
Rated voltage
D.C. 10.8 V - 12 V max
Standard battery cartridge
BL1016 / BL1021B / BL1041B
Net weight
1.2 - 1.3 kg (2.6 - 2.9 lbs)
1.2 - 1.4 kg (2.7 - 3.0 lbs)
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
Specifications and battery cartridge may differ from country to country.
The weight may differ depending on the attachment(s), including the battery cartridge. The lightest and heavi
-
est combination, according to EPTA-Procedure 01/2014, are shown in the table.
SAFETY WARNINGS
General power tool safety warnings
WARNING:
Read all safety warnings, instruc-
tions, illustrations and specifications provided with this
power tool.
Failure to follow all instructions listed below
may result in electric shock, fire and/or serious injury.
Save all warnings and instruc
-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or BATTERY-
operated (cordless) power tool.
Work area safety
1.
Keep work area clean and well lit.
Cluttered or
dark areas invite accidents.
2.
Do not operate power tools in explosive atmo
-
spheres, such as in the presence of flammable
liquids, gases or dust.
Power tools create sparks
which may ignite the dust or fumes.
3.
Keep children and bystanders away while
operating a power tool.
Distractions can cause
you to lose control.
Electrical Safety
1.
Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools.
Unmodified plugs and matching outlets will
reduce risk of electric shock.
2.
Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators.
There is an increased risk of elec
-
tric shock if your body is earthed or grounded.
3.
Do not expose power tools to rain or wet con-
ditions.
Water entering a power tool will increase
the risk of electric shock.
4.
Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges
or moving parts.
Damaged or entangled cords
increase the risk of electric shock.
5.
When operating a power tool outdoors, use an
extension cord suitable for outdoor use.
Use of
a cord suitable for outdoor use reduces the risk of
electric shock.
6.
If operating a power tool in a damp location is
unavoidable, use a ground fault circuit inter
-
rupter (GFCI) protected supply.
Use of a GFCI
reduces the risk of electric shock.
7.
Power tools can produce electromagnetic fields
(EMF) that are not harmful to the user.
However,
users of pacemakers and other similar medical
devices should contact the maker of their device and/
or doctor for advice before operating this power tool.
Personal Safety
1.
Stay alert, watch what you are doing and use
common sense when operating a power tool.
Do not use a power tool while you are tired or
under the influence of drugs, alcohol or med
-
ication.
A moment of inattention while operating
power tools may result in serious personal injury.
2.
Use personal protective equipment. Always
wear eye protection.
Protective equipment such
as dust mask, non-skid safety shoes, hard hat, or
hearing protection used for appropriate conditions
will reduce personal injuries.
3.
Prevent unintentional starting. Ensure the
switch is in the off-position before connecting
to power source and/or BATTERY pack, pick-
ing up or carrying the tool.
Carrying power tools
with your finger on the switch or energising power
tools that have the switch on invites accidents.
4.
Remove any adjusting key or wrench before
turning the power tool on.
A wrench or a key left
attached to a rotating part of the power tool may
result in personal injury.