SR6001 RS-232C Control Specification Page: 10 / 19 Document Version [1.00] 5-1-2. Display and Menu contents Command SLEEP VALUE OFF TOGGLE MENU CURSOR OFF ON ENTER UP DOWN LEFT RIGHT "SLP:0xx" (xx="00"~"90") "SLP:1" "MNU:0" (work same as RC) "MNU:1" "MNU:2" "MNU:3" "CUR:1" "CUR:2" "CUR:3" "CUR:4" Reply from Slave "SLP:01~90" ( ON ) "SLP:00" (OFF) "MNU:1" (Not on Menu) "MNU:2" (On Menu ) ACK DC TRG. Command TRG. 1 OFF TRG. 1 ON "DCT:11" (DC TRG. 1 OFF) "DCT:12" (DC TRG. 1 ON) Reply from Slave "DCT:ax" ( a: 1:OFF=1, ON=2) 'x' is fixed character e.g.) "DCT:1x" (TRG.1 OFF) "DCT:2x" (TRG.1 ON) Company Restricted

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

SR6001
RS-232C Control Specification
Page: 10 / 19
Document Version [1.00]
Company Restricted
5-1-2. Display and Menu contents
Command
Reply from Slave
VALUE
“SLP:0xx” (xx=”00”~”90”)
SLEEP
OFF
“SLP:1”
“SLP:01~90” ( ON )
“SLP:00” (OFF)
TOGGLE
“MNU:0”
(work same as RC)
OFF
“MNU:1”
ON
“MNU:2”
MENU
ENTER
“MNU:3”
“MNU:1” (Not on Menu)
“MNU:2” (On Menu )
UP
“CUR:1”
DOWN
“CUR:2”
LEFT
“CUR:3”
CURSOR
RIGHT
“CUR:4”
ACK
Command
Reply from Slave
TRG. 1 OFF
“DCT:11”
(DC TRG. 1 OFF)
DC TRG.
TRG. 1 ON
“DCT:12”
(DC TRG. 1 ON)
“DCT:ax”
( a: 1:OFF=1, ON=2)
‘x’ is fixed character
e.g.) “DCT:1x” (TRG.1 OFF)
“DCT:2x” (TRG.1 ON)