SR7300/SR7300OSE Hardware Software Interface (HSI) Spec. Page: 18 / 19 Document Version [2.01] 3-5-2. Special Status request and Status answer list Request Status SERIAL NUMBER Char. & Sample Status answer 'n' ("@1?n", 0x0D) SERIAL NUMBER Char. & Sample "n0XXXXXXXXX" ("@1n0123456789",0x0D) ERROR DETECT see blow 'm' ("@1?m", 0x0D) m0#$%& ("@1m0#$%&",0x0D) No error m- ("@1m-",0x0D) Descriptions of ERROR DETECT status answer character. (about : #$%&) (Character #, $, % and & would be '0' to '9' or 'A' to 'F', it uses to as hex. bit data.) * # : Bit ErrorName ERROR SAFE 3 Reserved 1 1 2 Reserved 0 0 1 Reserved 0 0 0 Reserved 0 0 * $ : Bit ErrorName 3 Reserved 2 Reserved 1 PROTECT 0 DSP1 ERROR ERROR 0 0 1 1 SAFE 0 0 0 0 * % : Bit ErrorName 3 Reserved 2 DSP2 ERROR 1 ADC ERROR 0 EEPROM ERROR ERROR 1 1 1 1 SAFE 1 0 0 0 * & : Bit ErrorName 3 EEPROM IF ERROR 2 DSP CODE ERROR 1 RS232C ERROR 0 POWER 5V ERROR ERROR 1 1 1 1 SAFE 0 0 0 0 ex.) * If the POWER 5V ERROR only occurs that will send ["@1m08081",0x0D]. * If the RS232C ERROR only occurs that will send ["@1m08082",0x0D]. * If the ADC ERROR only occurs that will send ["@1m080A0",0x0D]. * If the DSP1 ERROR only occurs that will send ["@1m09080",0x0D].

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

Hardware Software Interface (HSI) Spec.
Page: 18 / 19
SR7300/SR7300OSE
Document Version [2.01]
3-5-2. Special Status request and Status answer list
Request Status
Char. & Sample
Status answer
Char. & Sample
SERIAL NUMBER
‘n’ ("@1?n", 0x0D)
SERIAL NUMBER
“n0XXXXXXXXX”
("@1n0123456789",0x0D)
see blow
m0#$%&
(“@1m0#$%&”,0x0D)
ERROR DETECT
‘m’ ("@1?m", 0x0D)
No error
m- (“@1m-“,0x0D)
Descriptions of ERROR DETECT status answer character. (about : #$%&)
(Character #, $, % and & would be ‘0’ to ‘9’ or ‘A’ to ‘F’, it uses to as hex. bit data.)
* # :
Bit ErrorName
ERROR
SAFE
3 Reserved
1
1
2 Reserved
0
0
1 Reserved
0
0
0 Reserved
0
0
* $ :
Bit ErrorName
ERROR
SAFE
3 Reserved
0
0
2 Reserved
0
0
1 PROTECT
1
0
0 DSP1 ERROR
1
0
* % :
Bit ErrorName
ERROR
SAFE
3 Reserved
1
1
2 DSP2 ERROR
1
0
1 ADC ERROR
1
0
0 EEPROM ERROR
1
0
* & :
Bit ErrorName
ERROR
SAFE
3 EEPROM IF ERROR
1
0
2 DSP CODE ERROR
1
0
1 RS
232
C ERROR
1
0
0 POWER
V ERROR
1
0
ex.)
* If the POWER 5V ERROR only occurs that will send [“@1m08081”,0x0D].
* If the RS232C ERROR only occurs that will send [“@1m08082”,0x0D].
* If the ADC ERROR only occurs that will send [“@1m080A0”,0x0D].