Maytag CWE4800ACB Installation Instructions - Page 6

Wire Cable from Home Power Supply, Wire Cable from Home Power Supply - U.S. Only - black

Page 6 highlights

4-Wire Cable from Home Power Supply IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction and in Canada. A B E F G C H D I A. Cable from home power supply B. Black wires C. Red wires D. 4-wire flexible conduit from oven E. Junction box F. White wires G. UL listed wire connectors H. Green (or bare) ground wires I. UL listed or CSA approved conduit connector 1. Connect the 2 black wires (B) together using a UL listed wire connector. 2. Connect the 2 red wires (C) together using a UL listed wire connector. 3. Untwist white wire from green (or bare) ground wire coming from the oven. 4. Connect the 2 white wires (F) together using a UL listed wire connector. 5. Connect the green (or bare) ground wire (H) from the oven cable to the green (or bare) ground wire (in the junction box) using a UL listed wire connector. 6. Install junction box cover. 3-Wire Cable from Home Power Supply - U.S. Only IMPORTANT: Use the 3-wire cable from home power supply where local codes permit a 3-wire connection. A B C G H D E I F A. Cable from home power supply B. Junction box C. Black wires D. White wires E. Green (or bare) ground wire (from oven) F. 4-wire flexible conduit from oven G. Red wires H. UL listed wire connectors I. UL listed or CSA approved conduit connector 1. Connect the 2 black wires (C) together using a UL listed wire connector. 2. Connect the 2 white wires (D) and the green (or bare) ground wire (of the oven cable) using a UL listed wire connector. 3. Connect the 2 red wires (G) together using a UL listed wire connector. 4. Install junction box cover. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

6
4-Wire Cable from Home Power Supply
IMPORTANT:
Use the 4-wire cable from home power supply in
the U.S. where local codes do not allow grounding through
neutral, New Branch circuit installations (1996 NEC), mobile
homes and recreational vehicles, new construction and in
Canada.
1.
Connect the 2 black wires (B) together using a UL listed wire
connector.
2.
Connect the 2 red wires (C) together using a UL listed wire
connector.
3.
Untwist white wire from green (or bare) ground wire coming
from the oven.
4.
Connect the 2 white wires (F) together using a UL listed wire
connector.
5.
Connect the green (or bare) ground wire (H) from the oven
cable to the green (or bare) ground wire (in the junction box)
using a UL listed wire connector.
6.
Install junction box cover.
3-Wire Cable from Home Power Supply - U.S. Only
IMPORTANT:
Use the 3-wire cable from home power supply
where local codes permit a 3-wire connection.
1.
Connect the 2 black wires (C) together using a UL listed wire
connector.
2.
Connect the 2 white wires (D) and the green (or bare) ground
wire (of the oven cable) using a UL listed wire connector.
3.
Connect the 2 red wires (G) together using a UL listed wire
connector.
4.
Install junction box cover.
A. Cable from home power supply
B. Black wires
C. Red wires
D. 4-wire flexible conduit from
oven
E. Junction box
F. White wires
G. UL listed wire connectors
H. Green (or bare) ground wires
I. UL listed or CSA approved
conduit connector
A
B
C
D
E
F
G
H
I
A. Cable from home power supply
B. Junction box
C. Black wires
D. White wires
E. Green (or bare) ground wire
(from oven)
F. 4-wire flexible conduit from
oven
G. Red wires
H. UL listed wire connectors
I. UL listed or CSA approved
conduit connector
B
C
D
E
F
H
G
A
I