Maytag MEDB200VQ Installation Instructions - Page 4
Location Requirements - electric dryer
UPC - 883049140445
View all Maytag MEDB200VQ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
LOCATION REQUIREMENTS INSTALLATION CLEARANCES Location must be large enough to allow dryer door to open fully. DRYER DIMENSIONS Dryer with extended back: Dryer with flat back: 30" (783 mm) 221/4" (565 mm) 28" (711 mm) 431/2" (783 mm) You will need: ■■ A location allowing for proper exhaust installation. See "Venting Requirements." ■■ A separate 30 amp circuit. ■■ If using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See "Electrical Requirements." ■■ Floor must support dryer weight of 200 lbs. (90.7 kg). Also consider weight of companion appliance. ■■ Level floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly. ■■ For a garage installation, place dryer at least 18" (457 mm) above floor. If using a pedestal, you will need 18" (457 mm) to bottom of dryer. ■■ Steam models only: Cold water faucets located within 4 ft. (1.2 m) of the water fill valves, and water pressure of 20-100 psi (137.9-689.6 kPa). You may use the water supply for your washer using the "Y" connector and short hose (if needed) which are provided. For each arrangement, consider allowing more space for ease of installation and servicing; spacing for companion appliances and clearances for walls, doors, and floor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required. IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 45° F (7° C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times. Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. 4 NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See "Venting Requirements." Spacing for recessed area or closet installation All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance on sides and rear. ■■ Additional spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, door, and floor moldings. ■■ Additional spacing should be considered on all sides of the dryer to reduce noise transfer. ■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilitation openings are acceptable. ■■ Companion appliance spacing should also be considered. 18"* (457 mm) 14" max.* (356 mm) 1" (25 mm) 29" (737 mm) 1" (25 mm) Recessed area 1" (25 mm) 30" (783 mm) 5" (127 mm) Side view - closet or confined area (Dryer with extended back) 14" max.* (356 mm) 48" 2* (310 cm2) 3"* (76 mm) 1" (25 mm) 28" (711 mm) 5" (127 mm) Side view - closet or confined area (Dryer with flat back) 24" 2* (155 cm2) 3"* (76 mm) Closet door with vents * Required spacing