Maytag MEDE300VF Use and Care Guide - Page 6
Recommended installation spacing for cabinet installation - dryer
UPC - 883049135649
View all Maytag MEDE300VF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Custom undercounter installation - Dryer only 0" (0 cm) 38" min. (96.52 cm) 1"* (2.5 cm) *Required spacing Closet installation - Dryer only 27" (68.6 cm) 14" max.* (35.6 cm) 18" min.* (45.72 cm) 48 in.2* (310 cm2) 1"* (2.5 cm) 3"* (7.6 cm) 24 in.2* (155 cm2) 1"* 31½" 5"** (2.5 cm) (80 cm) (12.7 cm) A B A. Side view - closet or confined area B. Closet door with vents *Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed. 3"* (7.6 cm) Recessed or closet installation - Dryer on pedestal 14" max.* (35.6 cm) 18" min.* (45.72 cm) 1" (2.5 cm) 27" (68.6 cm) A 1" 1"* (2.5 cm) (2.5 cm) 31½" (80 cm) B 5"** (12.7 cm) A. Recessed area B. Side view - closet or confined area *Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed. Recommended installation spacing for cabinet installation For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required. 7"* (17.8 cm) 7"* (17.8 cm) 9"* (22.9 cm) 5"** 31¹ ₂" 1"* 1" 27" 1" (12.7 cm) (80.0 cm) (2.5 cm) (2.5 cm)(68.6 cm) (2.5 cm) *Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed. 6