NEC 4P-B75EJ2U Operation Manual - Page 53

Communication conditions, Communication procedure

Page 53 highlights

[ENGLISH] Contents 1. Part Names 2. Introduction 3. Direct Button Operation 4. On-Screen Display Menu 5. Application 6. Using a PC 1. Control of the TV 2. PC Compatibility Chart/AV Compatibility Chart 7. Appendix 8. Specifications 9. Trademarks 10. Dimensional Drawings >> Using a PC

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

[ENGLISH]
Contents
1. Part Names
2. Introduction
3. Direct Button Operation
4.
On-Screen Display Menu
5. Application
6. Using a PC
1. Control of the TV
2.
PC Compatibility Chart/AV
Compatibility Chart
7. Appendix
8. Specifications
9. Trademarks
10. Dimensional Drawings
Ver. 1.0.0
>>
<<
Communication conditions
Set the RS-232C communication settings on the computer to match
the monitor’s
communication settings as follows:
Baud rate
9600bps
Data length
8 bits
Parity bit
None
Stop bit
1 bit
Flow control
None
C1
C2
C3
C4
P1
P2
P3
P4
Communication procedure
Command format
When a command is sent from the computer to the monitor, the monitor operates
according to the received command and sends a response message to the
computer.
Return code
Command field
(4 prescribed
alphanumerical characters)
Parameter field
(4 character string comprised of:
0-9, +, -, space, ?)
Example: VOLM0030
VOLM
30
*
Be sure to input 4 characters for the parameter. Pad with
spaces
(“
”) if
necessary.
(“
is a return code (0D
H
, 0A
H
or 0D
H
)) Wrong
: VOLM30
Right
: VOLM
30
The current value can be returned by using
“?”
as the parameter.
Example:
VOLM
?
30
From computer to monitor (How
much is current volume setting?).
From monitor to computer
(Current volume setting: 30).
Response code format
When a command has been executed correctly
O
K
Return code
(0D
H
, 0A
H
)
A response is returned after a command is executed.
When a command has not been executed
E
R
R
Return code
(0D
H
, 0A
H
)
TIPS
“ERR”
is returned when there is no relevant command or when the command cannot
be used in the current state of the monitor.
If communication has not been established for reasons such as a bad connection
between the computer and monitor, nothing is returned (not even ERR).
“ERR”
may be returned when a command cannot be received correctly due to
interference from the surrounding environment.
Please ensure that the system or software resends the
command if this occurs.
Communication interval
After OK or ERR is returned, you must send the following commands.
To set a timeout for the command response, specify 10 seconds or longer.
Provide an interval of 100 ms or more between the command response and the
transmission of the next command.
en-US 52