ProSAFE® LAN Access and Aggregation Chassis Switches Data Sheet M6100 series Number of static routes IPv4 IPv6 Number of IP interfaces (port or VLAN) Jumbo frame support Acoustic noise (ANSI-S10.12) M6100-3S Base Chassis Heat Dissipation (BTU) M6100-3S Base Chassis XCM8948 blade XCM8944 blade XCM8944F blade XCM8924X blade Mean Time Between Failures (MTBF) M6100-3S Base Chassis XCM8948 blade XCM8944 blade XCM8944F blade XCM8924X blade XCM89P daughter card (PoE+) XCM89UP daughter card (UPOE) APS1000W power supply unit AFT603 fan tray L2 SERVICES - VLANS IEEE 802.1Q VLAN Tagging Protocol Based VLANs IP subnet ARP IPX Subnet based VLANs MAC based VLANs Voice VLAN Private Edge VLAN Private VLAN IEEE 802.1x Guest VLAN RADIUS based VLAN assignment via .1x RADIUS based Filter ID assignment via .1x MAC-based .1x Unauthenticated VLAN Double VLAN Tagging (QoQ) Enabling dvlan-tunnel makes interface Global ethertype (TPID) Interface ethertype (TPID) Customer ID using PVID GARP with GVRP/GMRP @ 25°C ambient (77°F) 53 dB 512 512 128 up to 12K packet size Fan speed control 17 Btu/hr 205 Btu/hr 239 Btu/hr 512 Btu/hr 682 Btu/hr @ 25°C ambient (77°F) 3,393,051 hours (~387.3 years) 862,954 hours (~98.5 years) 837,030 hours (~95.6 years) 694,849 hours (~79.3 years) 418,002 hours (~47.7 years) 8,253,931 hours (~942.2 years) 4,943,696 hours (~564.3 years) 1,272,908 hours (~145.3 years) 450,696 hours (~51.4 years) 10,020 Btu/hr with XCM89UP output at 2880W 8,423 Btu/hr with XCM89UP output at 2400W @ 50°C ambient (131°F) 791,646 hours (~90.4 years) 306,203 hours (~35 years) 302,649 hours (~34.5 years) 258,531 hours (~29.5 years) 144,699 hours (~16.5 years) 3,905,780 hours (~445.9 years) 2,430,081 hours (~277,4 years) 469,094 hours (~53.5 years) 80,820 hours (~9.2 years) Yes Up to 4,093 VLANs - 802.1Q Tagging Yes Yes Yes Yes Yes Yes Yes Based on phones OUI bytes (internal database, or user-maintained) or protocols (SIP, H323 and SCCP) Yes Yes Yes Yes Yes IP phones and PCs can authenticate on the same port Yes but under different VLAN assignment policies Yes Yes Yes Yes Yes Yes Yes Yes Automatic registration for membership in VLANs or in multicast groups Page 26 of 48

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Number of static routes
IPv4
IPv6
512
512
Number of IP interfaces (port or VLAN)
128
Jumbo frame support
up to 12K packet size
Acoustic noise (ANSI-S10.12)
@ 25°C ambient (77°F)
M6100-3S Base Chassis
53 dB
Fan speed control
Heat Dissipation (BTU)
M6100-3S Base Chassis
17 Btu/hr
XCM8948 blade
205 Btu/hr
10,020 Btu/hr with XCM89UP output at 2880W
XCM8944 blade
239 Btu/hr
8,423 Btu/hr with XCM89UP output at 2400W
XCM8944F blade
512 Btu/hr
XCM8924X blade
682 Btu/hr
Mean Time Between Failures (MTBF)
@ 25°C ambient (77°F)
@ 50°C ambient (131°F)
M6100-3S Base Chassis
3,393,051 hours (~387.3 years)
791,646 hours (~90.4 years)
XCM8948 blade
862,954 hours (~98.5 years)
306,203 hours (~35 years)
XCM8944 blade
837,030 hours (~95.6 years)
302,649 hours (~34.5 years)
XCM8944F blade
694,849 hours (~79.3 years)
258,531 hours (~29.5 years)
XCM8924X blade
418,002 hours (~47.7 years)
144,699 hours (~16.5 years)
XCM89P daughter card (PoE+)
8,253,931 hours (~942.2 years)
3,905,780 hours (~445.9 years)
XCM89UP daughter card (UPOE)
4,943,696 hours (~564.3 years)
2,430,081 hours (~277,4 years)
APS1000W power supply unit
1,272,908 hours (~145.3 years)
469,094 hours (~53.5 years)
AFT603 fan tray
450,696 hours (~51.4 years)
80,820 hours (~9.2 years)
L2 SERVICES - VLANS
IEEE 802.1Q VLAN Tagging
Yes
Up to 4,093 VLANs - 802.1Q Tagging
Protocol Based VLANs
IP subnet
ARP
IPX
Yes
Yes
Yes
Yes
Subnet based VLANs
Yes
MAC based VLANs
Yes
Voice VLAN
Yes
Based on phones OUI bytes (internal database, or
user-maintained) or protocols (SIP, H323 and SCCP)
Private Edge VLAN
Yes
Private VLAN
Yes
IEEE 802.1x
Guest VLAN
RADIUS based VLAN assignment via .1x
RADIUS based Filter ID assignment via .1x
MAC-based .1x
Unauthenticated VLAN
Yes
Yes
Yes
Yes
Yes
Yes
IP phones and PCs can authenticate on the same port
but under different VLAN assignment policies
Double VLAN Tagging (QoQ)
Enabling dvlan-tunnel makes interface
Global ethertype (TPID)
Interface ethertype (TPID)
Customer ID using PVID
Yes
Yes
Yes
Yes
Yes
GARP with GVRP/GMRP
Yes
Automatic registration for membership
in VLANs or in multicast groups
ProSAFE® LAN Access and Aggregation Chassis Switches
Data Sheet
M6100 series