Netgear WAG302 WAG302v1 Reference Manual - Page 64

Using the Secure Telnet Interface, Remote Console Secure Shell SSH, Public Community Name - connect to cable modem

Page 64 highlights

ProSafe Dual Band Wireless Access Point WAG302 Reference Manual (802.11a/g) • Remote Console Secure Shell (SSH): If set to Enable, the Wireless Access Point will only allow remote access via Secure Shell and Secure Telnet. The default is Enable. • SNMP: Enable SNMP to allow the SNMP network management software, such as HP OpenView, to manage the wireless access point via SNMPv1/v2 protocol. • Public Community Name: The community string to allow the SNMP manager to read the wireless access point's MIB objects. The default is Public. • Private Community Name: The community string to allow the SNMP manager to read and write the wireless access point's MIB objects. The default is Private. • IP address to Receive Traps: The IP address of the SNMP manager to receive traps sent from the wireless access point. The default is 0.0.0.0. Using the Secure Telnet Interface The WAG302 includes a secure Telnet command line interface (CLI). You can access the CLI from a secure Telnet client over the Ethernet port or over the serial console port. Note: You must use a secure Telnet client such as Absolute Telnet. Also, when you configure the client, use the SSH1, 3DES option. If you use the Telnet client to connect over the Ethernet port, use the IP address of the WAG302 as the host name. To use the CLI from a Console Port: 1. Using the null-modem cable, connect a VT100/ANSI terminal or a workstation to the port labeled Console. If you attached a PC, Apple Macintosh, or UNIX workstation, start a secure terminalemulation program. 2. Configure the terminal-emulation program to use the following settings: • Baud rate: 9,600 bps • Data bits: 8 • Parity: none • Stop bit: 1 • Flow control: none These settings appear below the connector on the back panel. 3. Press Return. The screen shown below in Figure 3-2 should appear. 3-2 Management v2.0, May 2006

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

ProSafe Dual Band Wireless Access Point WAG302 Reference Manual (802.11a/g)
3-2
Management
v2.0, May 2006
Remote Console Secure Shell (SSH):
If set to Enable, the Wireless Access Point will
only allow remote access via Secure Shell and Secure Telnet. The default is Enable.
SNMP:
Enable SNMP to allow the SNMP network management software, such as HP
OpenView, to manage the wireless access point via SNMPv1/v2 protocol.
Public Community Name
: The community string to allow the SNMP manager to read the
wireless access point's MIB objects. The default is Public.
Private Community Name
: The community string to allow the SNMP manager to read
and write the wireless access point's MIB objects. The default is Private.
IP address to Receive Traps:
The IP address of the SNMP manager to receive traps sent
from the wireless access point. The default is 0.0.0.0.
Using the Secure Telnet Interface
The WAG302 includes a secure Telnet command line interface (CLI). You can access the CLI
from a secure Telnet client over the Ethernet port or over the serial console port.
To use the CLI from a Console Port:
1.
Using the null-modem cable, connect a VT100/ANSI terminal or a workstation to the port
labeled Console.
If you attached a PC, Apple Macintosh, or UNIX workstation, start a secure terminal-
emulation program.
2.
Configure the terminal-emulation program to use the following settings:
Baud rate: 9,600 bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none
These settings appear below the connector on the back panel.
3.
Press
Return
. The screen shown below in
Figure 3-2
should appear.
Note:
You must use a secure Telnet client such as Absolute Telnet. Also, when you
configure the client, use the SSH1, 3DES option. If you use the Telnet client to
connect over the Ethernet port, use the IP address of the WAG302 as the host name.