Netgear WC7500-Wireless Product Data Sheet - Page 8

Technical Specifications

Page 8 highlights

ProSAFE® WC7500 Wireless Controller Data Sheet WC7500 Technical Specifications Physical Characteristics Power • 100-240V AC Universal Physical Dimensions (1 RU) • Dimensions (L x W x H): 440 x 262 x 43 mm (17.34 x 10.30 x1.7 in) Weight • 3.6 kg (7.9 lb) Environmental Conditions Operating Temperature • 32° to 113° F (0° to 45° C) Storage Temperature • -4° to 150° F (-20° to 70° C) Operating Relative Humidity • Minimum 10% • Maximum 90% Storage Humidity • Minimum 5% • Maximum 95% MTBF • WC7500 (@25C): 664,072 hours • Fan Tray (@25C): 676,058 hours • Power Supply (@25C): 938,490 hours Power Consumption • Maximum: 13W Compliance • ENGR 10049 EST Environmental Stress Test Guideline • ENGR 10045 EVT Engineering Validation Test Guideline • ENGR 10048 CVT Compliance Validation Test Guideline • ENGR 10046 SVT System Validation Test Guideline • ENGR 10023 HALT Highly Accelerated Life Test Guideline • ENGR 10036 CDG Component Derating Guideline Capacity Managed APs • 15 per controller WLANs (BSSIDs) • 144 Concurrent Stations • 2,000 per controller Guest Portal Profile Groups per Controller • 9 (1 Basic + 8 Advanced) Profile per Controller • 128 Security Profile Groups per Profile Group • 9 (1 Basic + 8 Advanced) Detectable rogue AP • Maximum: 512 Features • Layer 2 Discovery • Layer 3 Discovery • L2 Roaming • L3 Roaming • Layer 2 isolation • Access List • Auto Channel Allocation • Radius, AD, and LDAP proxy • Remote AP • Client load balancing • Bandsteering • Auto Power Control • Coverage Hole Detection • Rate Limiting on per SSID • Rate Limiting on per client • 802.11e WMM • Schedule AP on/off • Captive Portal • Heatmap Page 8 of 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

ProSAFE
®
WC7500 Wireless Controller
Data Sheet
WC7500
Page 8 of 9
Physical Characteristics
Power
100-240V AC Universal
Physical Dimensions (1 RU)
Dimensions (L x W x H):
440 x 262 x 43 mm
(17.34 x 10.30 x1.7 in)
Weight
3.6 kg (7.9 lb)
Environmental Conditions
Operating Temperature
32° to 113° F
(0° to 45° C)
Storage Temperature
-4° to 150° F
(-20° to 70° C)
Operating Relative Humidity
Minimum 10%
Maximum 90%
Storage Humidity
Minimum 5%
Maximum 95%
MTBF
WC7500 (@25C): 664,072 hours
Fan Tray (@25C): 676,058 hours
Power Supply (@25C): 938,490 hours
Power Consumption
Maximum: 13W
Compliance
ENGR 10049 EST Environmental Stress
Test Guideline
ENGR 10045 EVT Engineering Validation
Test Guideline
ENGR 10048 CVT Compliance Validation
Test Guideline
ENGR 10046 SVT System Validation Test
Guideline
ENGR 10023 HALT Highly Accelerated Life
Test Guideline
ENGR 10036 CDG Component Derating
Guideline
Capacity
Managed APs
15 per controller
WLANs (BSSIDs)
144
Concurrent Stations
2,000 per controller
Guest Portal
Profile Groups per Controller
9 (1 Basic + 8 Advanced)
Profile per Controller
128
Security Profile Groups per Profile Group
9 (1 Basic + 8 Advanced)
Detectable rogue AP
Maximum: 512
Features
Layer 2 Discovery
Layer 3 Discovery
L2 Roaming
L3 Roaming
Layer 2 isolation
Access List
Auto Channel Allocation
Radius, AD, and LDAP proxy
Remote AP
Client load balancing
Bandsteering
Auto Power Control
Coverage Hole Detection
Rate Limiting on per SSID
Rate Limiting on per client
802.11e WMM
Schedule AP on/off
Captive Portal
Heatmap
Technical Specifications