Nikon 1683 Instruction Manual - Page 23
exposure, measurement
View all Nikon 1683 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Stop-down exposure measurement This exposure measurement method is used when the diaphragm on the lens does not link with the meter coupling lever on the camera body, such as when a non-AI lens or an extension ring is mounted on the camera. The procedure is as follows: 1) Set the ASA/ ISO number. 2) Compose your picture and·secure subject focus . 3) Press the shutter release button lightly to turn the meter on. 4) Perform exposure measurement, depending on the type of lens used: • Lens with automatic diaphragm Determine the correct exposure while pressi ng the depth- of-field preview lever ® , then take your finger off the lever and depress the shutter release button . • Lens without automatic diaphragm (PC -Nikkor lens) First, determine the correct exposure by adjusting the shutter speed and aperture. Then, focus at full aperture. Shift the lens so that you get the desired composition. Return the aperture setting to the preset posi tion and shoot. • Lens with fixed aperture (Reflex -Nikkor lens) Exposure cannot be changed according to the aperture because in this type of lens, the aperture is fixed. Determine the correct exposure by turning the shutter speed dial. If correct exposure is unobtainable, use an ND (neu tral den sity) filter or change the illumination to adjust the exposure . 23