Oki B4200 Network User's Guide for OkiLAN 6020e - Page 131
Appendix A, Troubleshooting, Main Status Indicator, Restoring the OkiLAN 6020e to, Factory Defaults
View all Oki B4200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 131 highlights
Section 4 - Appendix A - Troubleshooting Appendix A Troubleshooting Main Status Indicator Upon power-up, the main status indicator flashes orange. It changes to green when the OkiLAN 6020e passes self-test. The indicator stays orange if the OkiLAN 6020e fails self-test. If the indicator turns solid orange due to an error, a configuration sheet will be printed automatically. Check the error message reported on the configuration sheet. Restoring the OkiLAN 6020e to Factory Defaults In most cases, the best way to restore the OkiLAN 6020e to factory defaults is via telnet. However, if you are unable to connect to the device because of a configuration error, use the following method which does not require a network connection. To restore the OkiLAN 6020e to factory defaults, complete the following steps: 1. Power down the OkiLAN 6020e. 2. While holding in the Print Configuration Sheet Test button, power up the OkiLAN 6020e. Hold the button until the status indicator turns solid green. 3. Power cycle the OkiLAN 6020e. It will have restored itself to defaults. TCP/IP OKI OkiLAN 6020e User's Guide IV - 49