Oki C710dn C710 User's Guide, English - Page 39

Ascii, I0

Page 39 highlights

ITEM SETTINGS Print Setup (cont.) PS Setup X Dimension Y Dimension 64 mm ~ 210 mm ~ 216 mm 127 mm ~ 297 mm ~ 1220 mm Network Protocol ASCII/RAW Parallel Protocol ASCII/RAW USB Protocol ASCII/RAW PCL Setup Font Source Font Number Resident I0 ~ I90 EXPLANATION Specifies paper width of Custom paper as a default value. Sets a paper size at right angles to the paper run direction. Specifies paper length of Custom paper as a default value. Sets a paper size in the same direction as the paper run direction. Specifies PS communication protocol mode of data from NIC port. (In RAW mode, Ctrl-T is invalid). PS models only. Specifies PS communication protocol mode of data from Centronics port. (In RAW mode, Ctrl-T is invalid). PS models only. Specifies PS communication protocol mode of data from USB port. (In RAW mode, Ctrl-T is invalid). PS models only. Specifies the location of PCL default font. Sets the PCL font number. The valid range of this variable changes depending on the FONT SOURCE setting at the time. If the default font is set for FONT SOURCE, the number starts at 0. If it is not, the number starts at 1. The maximum value is equal to the number of fonts installed in FONT SOURCE. 39 - C710n User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

39
– C710n User’s Guide
Print
Setup
(cont.)
PS Setup
X
Dimension
64 mm
~
210 mm
~
216 mm
Specifies paper width of
Custom paper as a default
value.
Sets a paper size at right angles
to the paper run direction.
Y
Dimension
127 mm
~
297 mm
~
1220 mm
Specifies paper length of
Custom paper as a default
value.
Sets a paper size in the same
direction as the paper run
direction.
Network
Protocol
ASCII/
RAW
Specifies PS communication
protocol mode of data from NIC
port.
(In RAW mode, Ctrl-T is
invalid). PS models only.
Parallel
Protocol
ASCII
/RAW
Specifies PS communication
protocol mode of data from
Centronics port.
(In RAW mode, Ctrl-T is
invalid). PS models only.
USB
Protocol
ASCII/
RAW
Specifies PS communication
protocol mode of data from USB
port.
(In RAW mode, Ctrl-T is
invalid). PS models only.
PCL
Setup
Font
Source
Resident
Specifies the location of PCL
default font.
Font
Number
I0 ~
I90
Sets the PCL font number.
The valid range of this variable
changes depending on the
FONT SOURCE setting at the
time. If the default font is set
for FONT SOURCE, the number
starts at 0. If it is not, the
number starts at 1. The
maximum value is equal to the
number of fonts installed in
FONT SOURCE.
ITEM
SETTINGS
EXPLANATION