Optoma TW775 User's Manual - Page 66
LED Error Code Messages, Fan4 error Power Fan
View all Optoma TW775 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Appendices LED Error Code Messages Error Code Message Power LED Lamp LED (Blink) (Blink) T1 temperature over temperature 3 0 Thermal Break 4 0 G794 fail 4 4 T1 fail 4 5 Lamp error 5 0 Ballast Over Temperature 5 1 Ballast shot circuit in output detected 5 2 End of lamp lift detected 5 3 Ballast lamp did not ignite 5 4 Lamp extinguished during normal operation 5 5 Lamp extinguished during run-up phase 5 6 Fan1 error (Lamp Fan) 6 1 Fan2 error (Ballast Fan) 6 2 Fan3 error (Burner Fan) 6 3 Fan4 error (Power Fan) 6 4 Lamp door open 7 0 DMD error 8 0 Color wheel error 9 0 English 66
English
ยตยต
LED Error Code Messages
Error Code Message
Power LED
Lamp LED
(Blink)
(Blink)
T1 temperature over temperature
3
0
Thermal Break
4
0
G794 fail
4
4
T1 fail
4
5
Lamp error
5
0
Ballast Over Temperature
5
1
Ballast shot circuit in output detected
5
2
End of lamp lift detected
5
3
Ballast lamp did not ignite
5
4
Lamp extinguished during normal opera-
tion
5
5
Lamp extinguished during run-up phase
5
6
Fan1 error (Lamp Fan)
6
1
Fan2 error (Ballast Fan)
6
2
Fan3 error (Burner Fan)
6
3
Fan4 error (Power Fan)
6
4
Lamp door open
7
0
DMD error
8
0
Color wheel error
9
0
Appendices