Panamax M4320-PRO Manual

Panamax M4320-PRO Manual

Panamax M4320-PRO manual content summary:

  • Panamax M4320-PRO | Manual - Page 1
    M4320-PRO Instructions M4320-PRO REBOOT 1 REBOOT 2 1 2 OUTLET STATUS 3 4 5 6 7 8 BlueB LT™ ENABLED BRIGHTNESS VOLTS UNSAFE VOLTAGE BREAKER WIRING FAULT TEMPERATURE 20 A Power Management with Control System Interactive Functionality. • 20 Amp Capacity M4320-PRO • 8 Individually
  • Panamax M4320-PRO | Manual - Page 2
    control and monitoring for the M4320-PRO. Table of Contents Feature Descriptions...pg. 1 Important Safety Instructions, Front Panel Features Overview...pg. 2 Preset Profile Information...pg. 3 Rear Panel Features Overview, Bubble of Protection...pg. 4 BlueBOLT™ Setup, Registration, Trouble Shooting
  • Panamax M4320-PRO | Manual - Page 3
    than the capacity of the surge protection components, the M4320-PRO's Protect or Disconnect Circuitry will disconnect your equipment in order to protect it. The M4320-PRO will need to be repaired or replaced by Panamax if this occurs within the product's 3 year warranty. 4 Isolated Outlet Banks
  • Panamax M4320-PRO | Manual - Page 4
    instructions. 5. WARNING: Do not use this apparatus near water. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 6. CAUTION - Contains Always On Receptacles. To reduce risk of shock - Disconnect M4320-PRO from power source before servicing control,
  • Panamax M4320-PRO | Manual - Page 5
    on) DC TRIGGER ON: 5(on)→(20 sec)→7(on)→(20 sec)→8 (on) DC TRIGGER OFF: 8(off)→(20 sec)→7(off)→(30 sec)→5(off) PROFILE 4 (P4) NETWORK + CONTROL DELAYS OUTLET SEQUENCING (profile P4, by outlet #s): With switching on and off BREAKER or holding both REBOOT buttons. Start up: 1→(15 sec)→2→(15 sec
  • Panamax M4320-PRO | Manual - Page 6
    1. Power inlet: M4320-PRO Panamax MOD-series signal protection protection pass-through. capabilities. AC INLET OUTLET 8 OUTLET 7 OUTLET 6 OUTLET 5 OUTLET 4 OUTLECTA3TV / SATO1UTLET 2CATV / SAOTUT2LET 1 BlueBOLT-CV1BlueBOLT-CV1 3. Outlets: all rearGROpUNaDnel outlets are separately controlled
  • Panamax M4320-PRO | Manual - Page 7
    M4320-PRO Power Management Component is completely plug-and-play and does not require any software installation or network configuration (including configuring of network ports). The online BlueBOLT™ control interface is operated through your web browser. Troubleshooting • Is your Power Management
  • Panamax M4320-PRO | Manual - Page 8
    Identify Connected Equipment Use this diagram to write in what pieces of equipment are plugged into each outlet for an easy reference. Please note that the outlets start at No. 8 on the left. The outlet indicator lights on the front panel are numbered 1 through 8 left to right. OUTLET 5 OUTLET 4
  • Panamax M4320-PRO | Manual - Page 9
    that you read the entire instructions list before proceeding. The BlueBOLT-CV1 should already be factory installed in this Panamax M4320-PRO component. To switch from BlueBOLT™ functionality to RS-232 connectivity, follow these steps: 1. Unplug M4320-PRO Power Management Component from AC wall
  • Panamax M4320-PRO | Manual - Page 10
    are commands sent by the controlling equipment to the M4320-PRO unit. Note: Responses are only transmitted if unsolicited feedback (§3.9) is enabled. 3.0 GREEN BUTTON 3.0.1 Command: !GREEN_BUTTON 3.0.2 Action: Power down or up, all outlets controlled by this trigger. Has the
  • Panamax M4320-PRO | Manual - Page 11
    ) or OFF (polled). When ON, a message will be sent to the controller every time the status of an input (i.e. trigger), output (i.e. outlet) or power state (i.e. overvoltage) changes. If feedback is OFF, the controller must poll for state changes. 3.9.1 Command: !SET_FEEDBACK mode mode
  • Panamax M4320-PRO | Manual - Page 12
    itself. 4.0.1 Query: ?ID 4.0.2 Response: $PANAMAX $MAX 4315-PRO $FIRMWARE: revision 4.1 FAULT STATUS Request status $OUTLET8 = status status = { ON, OFF } 4.4 POWER STATUS Request the status of the input voltage. 4.4.1 Query: ?POWERSTAT 4.4.2
  • Panamax M4320-PRO | Manual - Page 13
    TRIGGER STATUS CHANGE 5.2.1 Condition: When either front panel button or input trigger status changes, a status message is sent to the controller. 5.2.2 Message For BUTTON_1 press: $BUTTON_1 = TRIGGERED For BUTTON_2 press: $BUTTON_2 = TRIGGERED If input trigger is switched ON
  • Panamax M4320-PRO | Manual - Page 14
    M4320-PRO Specifications AC Power Line Voltage 120V, 60Hz Isolated Banks 4 Voltage Regulation No Total Outlets 9 Outlets High Current Outlets 2 Outlets Total Current Capacity M4320-PRO 20 A (2400W) Voltage Protection Rating (UL 1449 3rd Edition, 3,000A 330V Protection Modes L-N, L-G, N-G
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

1
2
3
4
5
6
7
8
UNSAFE VOLTAGE
BREAKER
WIRING FAULT
TEMPERATURE
20 A
BRIGHTNESS
OUTLET STATUS
REBOOT 1
REBOOT 2
M4320-PRO
B
LT
Blue
ENABLED
VOLTS
Power Management with Control System Interactive Functionality.
• 20 Amp Capacity M4320-PRO
• 8 Individually Controllable Rear Panel Outlets
• Fully Programmable
• TCP/IP (BlueBOLT™) Installed
• RS-232 Card (Included, not installed)
• Linear Filtration with 3 Isolated LiFT Filter Banks, 76db (5 kHz - 250 kHz), 46 db (250 kHz - 1 MHz)
• One Isolated Filter Bank for High Current Devices, 60db (5 kHz - 450 kHz), 46 db (450 kHz - 1 MHz)
• Front Panel Circuit Breaker
• Integrated Front Rack Ears
• 12 Volt Input Triggering
• Detachable 10 ft. Power Cord - 20A plug
• AVM & Protect-or-Disconnect Circuitry
M4320-PRO Instructions
INS00860 REV. D
5/10
Important:
You will need the BlueBOLT-CV1’s unique MAC address and challenge key (provided on the 2 labels
attached to the cover of the Quick Start Guide which is included in the M4320-PRO packaging). One label is
permanently adhered to the Quick Start Guide and the other is removable for your convenience.
B LT
Blue
ENABLED