Panamax M5100-EX Manual

Panamax M5100-EX Manual

Panamax M5100-EX manual content summary:

  • Panamax M5100-EX | Manual - Page 1
    plugged into the other outlet banks. Model: M5100-EX M5100-EX BANK 1 ALWAYS ON BANK 2 ON BANK 3 ON WIRING OK POWER AND FILTRATION INDICATOR LIGHTS 90V 95V 100V 105V 110V 115V 120V 125V 130V 135V Home Theater Power Conditioner Key Features Sequential Startup/Shutdown: Complex audio/video
  • Panamax M5100-EX | Manual - Page 2
    FILTRATION BANK 3 ON WIRING OK METER LIGHTS 90V 95V 100V 105V 110V 115V 120V 125V 130V 135V Home Theater Power Conditioner M5100 -EX Back Panel Connection Features Circuit Breaker Automatically opens when the current load is greater than 15 Amps. Push to reset. Outlet Bank 2 Four switched
  • Panamax M5100-EX | Manual - Page 3
    M5100-EX Specifications AC Power Line Voltage 120V, 60Hz Total Current Capacity 15 A UL1449 Suppression Rating 330V Protection Modes L-N, L-G, N-G Initial Clamping Level 200V Energy Dissipation 1815 Joules Peak Impulse Current 73,000 Amps Catastrophic Surge Circuit Yes Thermal Fusing Yes
  • Panamax M5100-EX | Manual - Page 4
    provided, shall determine whether or not your request is eligible for payment. If the surge protector shows no signs of AC power or signal line surge damage and is working within design specifications, Panamax will return the unit to you with a letter explaining the test results and notifying
  • Panamax M5100-EX | Manual - Page 5
    M5100-EX M5100-EX BANK 1 ALWAYS ON BANK 2 ON BANK 3 ON WIRING OK POWER AND FILTRATION INDICATOR LIGHTS 90V 95V 100V 105V 110V 115V 120V 125V 130V 135V Home Theater Power Conditioner y fiabilidad. El nivel de sujeción del protector de teléfono MAX® 5100-EX es de 260 voltios. Esto permitirá un
  • Panamax M5100-EX | Manual - Page 6
    95V 100V 105V 110V 115V 120V 125V 130V 135V Home Theater Power Conditioner M5100-EX Corta Circuito Automáticamente se abre cuando la cables Ethernet 10/100 base T. El cable entrante LAN DEBE estar enchufado al jack LINE. Cable de conexión al equipo DEBE ser enchufado a los jacks EQUIP. Jacks
  • Panamax M5100-EX | Manual - Page 7
    M5100-EX Protección Metálico y Longitudinal Jacks RJ-11 Alambres Protegidos 2-alambres, Patillas 4 & panamax.com Servicios de Cuidado a Cliente -7:30 AM - 4:30 PM, M-F Correo Electrónico - [email protected] © 2005 Panamax. Panamax, MAX y el logo de Panamax son marcas registradas de Panamax
  • Panamax M5100-EX | Manual - Page 8
    EX: $5,000,000 M5300-EX: $5,000,000 M5510-Pro: $5,000,000 M4310: $5,000,000 M5400-EX: $5,000,000 ML4200: $5,000,000 M4400: $5,000,000 M5410: $5,000,000 M5100-EX: $5,000,000 M5500-EX .panamax.com/support ** antes de retornar el protector a Panamax. En este entonces es cuando debe notificar a Panamax
  • Panamax M5100-EX | Manual - Page 9
    M5100-EX M5100-EX BANK 1 ALWAYS ON BANK 2 ON BANK 3 ON WIRING OK POWER AND FILTRATION INDICATOR LIGHTS 90V 95V 100V 105V 110V 115V 120V 125V 130V 135V Home Theater Power Conditioner service. Ce signal activera les sorties à interrupteur du MAX® 5100-EX de brevet de Panamax surveille sans
  • Panamax M5100-EX | Manual - Page 10
    100V 105V 110V 115V 120V 125V 130V 135V Home Theater Power Conditioner M5100-EX Disjoncteur Il s'ouvre automatiquement lorsque l'intensité du SAT CATV / ANT VOLTAGE SENSE TRIGGER INPUT 3 - 24VDC LAN LINE IN EQUIP. PHONE LINE IN EQUIP. Alimentation principale Ce cordon doit être branché sur
  • Panamax M5100-EX | Manual - Page 11
    M5100-EX Alimentation Modes de suppression Métallique et longitudinal Prises RJ-11 Fils protégés 2 fils, broches 4 et 5 www.panamax.com Relations avec la clientèle: 7 h 30 à 16 h 30, du lundi au vendredi Courriel : [email protected] Panamax, MAX et le logotype Panamax sont
  • Panamax M5100-EX | Manual - Page 12
    EX: 5 000 000 $ M5300-EX: 5 000 000 $ M5510-Pro: 5 000 000 $ M4310: 5 000 000 $ M5400-EX: 5 000 000 $ ML4200: 5 000 000 $ M4400: 5 000 000 $ M5410: 5 000 000 $ M5100-EX: 5 000 000 $ M5500-EX vous adresser au Service des relations avec la clientèle de Panamax au www.panamax.com/support. La présente
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

MAX
®
5100-EX Owner’s Guide
Your audio/video components are constantly
being bombarded by electromagnetic interfer-
ence (EMI) and radio frequency interference
(RFI) through their power cords.
This contam-
inated power can affect audio/video equipment
and will degrade the overall performance of
your entire system.
Common symptoms of
contaminated power include pops, hisses,
hums and visual artifacts.
The MAX 5100-EX is designed to filter this
noise, supply clean power to your system and
provide noise isolation between the outlet
banks so that any noise created by an A/V com-
ponent can not contaminate the power going to
equipment plugged into the other outlet banks.
Sequential Startup/Shutdown:
Complex audio/video systems may be suscep-
tible to voltage transients generated internally
at start-up/shutdown if all of the equipment is
powered on or off at the same time.
This can
cause speaker “thumps” which are not only
annoying but can also damage the speakers.
The MAX® 5100-EX is designed to eliminate
these transients by providing a “start-up” delay
for the High-Current outlets and a “shutdown”
delay for the Switched Outlet Bank.
This allows
the components plugged into the Switched
Outlet Bank to power-up and stabilize before
any amplifiers and powered sub-woofers are
turned on.
This sequence is reversed during
shutdown.
The amplifiers and powered sub-
woofers turn off, their power supplies drain,
and then the equipment plugged into the
Switched Outlet Bank is turned off.
Voltage Sense Trigger:
This feature provides an ON/OFF trigger for the
MAX® 5100-EX using a Direct Current voltage
signal.
Many components such as pre-ampli-
fiers and receivers have a DC trigger built in,
and will transmit a constant power signal when
turned on and in use.
The presence of this
power signal will turn on the MAX® 5100-EX’s
switched outlets.
When the source component
is turned off, the voltage trigger signal is also
turned off and the MAX ® 5100-EX’s shutdown
sequence is initiated.
An AC Adapter of the
appropriate voltage, plugged into a switched
outlet, may also be used if a DC trigger is not
built in.
The MAX® 5100-EX voltage sense trigger input
uses a standard 3.5mm (1/8") mini-plug jack.
This jack has an electrically isolated switch built
in.
If nothing is inserted into the input jack, the
voltage sense is bypassed and the Power
Button on the front panel has sole control of the
startup/shutdown sequence.
If a plug is insert-
ed into the input jack, the front panel switch is
bypassed and the voltage sense becomes the
startup/shutdown trigger.
IMPORTANT, Please
Note:
The unit needs to be plugged in, and in
the powered OFF state before inserting the DC
input trigger mini-plug.
Automatic Over & Under Voltage Protection:
Panamax’s patent pending power monitoring
circuitry constantly monitors the AC line volt-
age for unsafe voltage conditions such as pro-
longed over-voltages and under-voltages
(brownouts).
These unsafe conditions pose a
very dangerous threat to all electronic equip-
ment within the home.
If the MAX® 5100-EX
senses an unsafe power condition, it will auto-
matically
disconnect
your equipment from the
power to protect equipment from damage.
Once the voltage returns to a safe level, the
MAX® 5100-EX will automatically
reconnect
the power.
Protect or Disconnect AC Surge Protection:
When the MAX® 5100-EX is subjected to a
high voltage surge, its voltage output is limited
to a safe level and the high levels of surge cur-
rent are diverted away from the connected
equipment.
• When subjected to a 6,000V (open circuit
voltage) / 500A (short circuit current) surge,
the MAX® 5100-EX limits its voltage output to
less than 330V peak, UL’s best rating.
The
MAX® 5100-EX will withstand, without dam-
age, 20,000A surges, far exceeding the UL
requirement of only 3000 Ampere surges.
• If the magnitude of the surge is greater than
the capacity of the surge protection compo-
nents, the MAX® 5100-EX's Protect or
Disconnect‘ Circuitry will disconnect your
equipment in order to protect it.
The MAX®
5100-EX will need to be repaired or replaced by
Panamax if this occurs.
Application Specific Coaxial Signal Line
Protection:
Panamax's exclusive SignalPerfect™ Technolo-
gy provides application specific protection for
your satellite and cable TV equipment.
One line
of protection is provided for each type.
The
satellite connection is for a coaxial cable con-
nected to a DBS (single LNB) satellite dish.
The
antenna connection is for a non-amplified off-
air antenna or cable TV line.
The protection circuitry has been optimized for
each application and is not interchangeable.
The jacks are not labeled In and Out.
The cir-
cuitry is bidirectional in both signal transmis-
sion and protection capabilities, making it com-
patible with the latest digital cable and satellite
technologies.
Cable TV (Including HDTV)
– TV tuners oper-
ate at approximately 10 millivolts (0.01 V) and
utilize the frequency spectrum up to 950 MHz.
The clamping level of the MAX® 5100-EX's
cable TV protection circuitry is 1400 millivolts
(1.4 volts).
That's less than 1 volt above nor-
mal operating levels.
The circuitry is also
shielded to prevent interference.
Satellite TV
- Satellite dish LNB's can require
up to 24 volts to operate and utilize the fre-
quency range of 950 MHz to 2.2 GHz.
The
clamping level of the MAX® 5100-EX's satellite
protection circuitry is 25 volts - just 1 volt
above the maximum operating voltage.
The
circuitry is also shielded to prevent interfer-
ence.
Telephone Line Protection:
Digital video recorders and satellite TV
receivers require a telephone line connection
for TV show scheduling and/or Pay-Per-View
services.
The MAX® 5100-EX also provides
surge protection for this line.
One pair of RJ-
11 telephone jacks is provided for this.
The cir-
cuitry utilizes auto-resetting PTCRs and solid-
state SIDACtors“ for reliability and unsur-
passed protection.
The clamping level of the
MAX 5100-EX's telephone protector is 260
volts.
This will allow typical ring voltage (90-
130VAC) and operating battery voltage (-48DC)
to pass through the circuit and still protect the
modem in your satellite receiver from damage.
Home Theater Power Conditioner
M5100-EX
POWER AND FILTRATION
BANK 1
ALWAYS ON
BANK 3
ON
WIRING
OK
INDICATOR
LIGHTS
BANK 2
ON
90V
95V
100V
105V
110V
115V
120V
125V
130V
135V
Key Features
LEVEL 3 EMI/RFI Noise Filtration with Isolation Between Outlet Banks:
Model:
M5100-EX
INS0785E
Rev A
5/05