Panamax M5400-PM Datasheet - Page 2

M5400-pm Back Panel Features, M5400-pm Specifications, Upc's, Quantities, Weights & Measurements

Page 2 highlights

M5400-PM BACK PANEL FEATURES 1. 15A Main Circuit Breaker: Automatically opens when the current load is greater than 15 Amps. Push to reset. 2. Outlet Bank 5 Two switched, high-current outlets controlled by the front panel Power Button or the DC Trigger input. Bank 5 has a 5 second turn on delay and turns off immediately upon shutdown. The High Current outlets provide power from a low impedance noise filtration circuit that does not limit the current to your equipment. Its output is noise-isolated from all other outlet banks. 3. Outlet Banks 3 and 4 Each bank features two switched outlets with voltage regulation and linear filtration technology (LiFT) controlled by the front panel Power Button or the DC Trigger input. Banks 3 & 4 will turn on immediately and turn off after a 10 second delay. LiFT EMI/RFI noise filtration is provided by a twostage balanced Pi filter which also provides noise isolation from all other outlet banks. 4. Outlet Banks 1 and 2 Each bank features two always-on outlets with voltage regulation and linear filtration technology (LiFT). Power will only be turned off under a fault condition. (See specifications for over-voltage and under-voltage thresholds). LiFT EMI/RFI noise filtration is provided by a two-stage balanced Pi filter which also provides noise isolation from all other outlet banks. 5. Universal Coaxial Connectors 3 pairs of bidirectional protection circuits optimized for satellite, cable, and antenna TV signal lines. 6. Main Power Cord 10ft. Must be plugged into a properly wired & grounded 3-wire outlet. 7. Ground Lug: Provides a common grounding point for equipment with separate ground leads. 8. Bank 1 & 2 Indicator Light Normally ON, is lit when there is power present on the Bank 1 and 2 receptacles. M5400-PM SPECIFICATIONS 9. Voltage Sense Trigger 10. Voltage Sense Trigger Output Input 3.5mm (1/8") Mini-Plug jack. 3.5mm (1/8") mono mini-plug. Connecting a trigger wire to Connect to a remote trigger the Voltage Sense Output jack device that uses a DC output will allow the input signal to to trigger a startup/shutdown pass through the M5400-PM to sequence. control the startup/shutdown of an additional device. 11. LAN Jacks Protection circuits for 10/100 baseT Ethernet lines. For the LAN 2 protected jacks, the incoming LAN line MUST be plugged into the LINE jack and the patch cord to the equipment MUST be plugged into the EQUIP jack. For the LAN 1 protected jacks the incoming LAN line must be plugged into the LINE jack and the equipment must be plugged into the gaming jack on the front panel. 8 wire protection, 60V ± 5V clamping. 12. Phone Jacks Protection circuits for standard telephone or pay-per-view lines. Phone circuit is autoresetting. Incoming phone cord MUST be plugged into the LINE jack. Patch cords to the equipment (satellite receiver, digital video recorder, telephone, etc.) MUST be plugged into the EQUIP jacks. General Dimensions 17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet) Weight...20 lbs. AC Power Line Voltage...120V, 60Hz Total Current Capacity 15 A (1800 W) Voltage Protection Rating (UL1449 3rd Edition, 3,000A 500V Protection Modes L-N, L-G, N-G Initial Clamping Level 200V Peak, 141 V RMS Energy Dissipation 2350 Joules Peak Impulse Current 75,000 Amps Catastrophic Surge Circuit Yes Thermal Fusing:...Yes Auto-resetting Over-voltage shutoff 142 VAC ± 8 VAC Auto-resetting Under-voltage shutoff 86 VAC ± 6 VAC EMI/RFI Noise Filtration Bank 1 Up to -86 db (100 KHz - 2 MHz) Bank 2 Up to -91 db (100 KHz - 2 MHz) Bank 3 Up to -81 db (100 KHz - 2 MHz) Bank 4 Up to -100 db (100 KHz - 2 MHz) Bank 5, High Current Outlets Up to -81 db (100 KHz - 2 MHz) Voltage Regulation (Banks 1-4 Power / Current 1500 VA / 12A Input Voltage Range 100-136 VAC Output Voltage Range 120 VAC ± 6 VAC Buck Stage reduces voltage in the 125-136 V range Boost Stage 1 boosts voltage in the 109-119 V range Boost Stage 2 boosts voltage in the 100-109 V range Design and specifications are subject to changes due to product upgrades and improvements. DC Trigger Input Jacks 3.5mm (1/8") mono mini-plug Voltage and Polarity 3 - 24V DC, Bidirectional Current Requirement 4.6 mA @3V, 58 mA @24V DC Trigger Output Pass through...no delay Positive = Tip, Negative = Ring LAN Protection Clamping Level...60V ± 5V Compatibility...10/100bT Connectors...RJ-45 Wires Protected:...8-Wires USB Circuit Jacks...USB-A Power Delivery 500 mA @ 5VDC Telco Protection Fuseless/Auto-resetting Yes Clamping Level...260V Capacitance...30pf (approx.) Suppression Modes Metallic & Longitudinal Wires Protected 2-Wire, Pins 4 & 5 Connectors...RJ-11 Universal Coax Protection HD 1080 i/p Ready...Yes Shielded...Yes Clamping Level...75V Frequency Range 0 MHz - 2.2 GHz Insertion Loss...< 0.5 dB Connectors Female "F", Gold Plated Bidirectional...Yes UPC'S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING MODEL M5400-PM UNIT CARTON MASTER CARTON Dimensions Weight Dimensions Weight UPC Qty Dimensions Weight UPC 17" x 12.75" x 3.5" 4.1" H with feet 20 lbs 23.25" x 19" x 9.25" 23 Lbs 0 50616 00815 0 1 23.75" x 19.75" x 10" 24 Lbs 5 00 50616 00815 5 1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 • 707-283-5900 • Fax 707-283-5901 • www.panamax.com © 2009 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax L591 REV. D 12/09

  • 1
  • 2

M5400-PM BACK PANEL FEATURES
1. 15A Main Circuit
Breaker:
Automatically opens
when the current load
is greater than 15
Amps. Push to reset.
4. Outlet Banks 1 and 2
Each bank features two always-on outlets with
voltage regulation and linear filtration technology
(LiFT). Power will only be turned off under a fault
condition. (See specifications for over-voltage
and under-voltage thresholds). LiFT EMI/RFI
noise filtration is provided by a two-stage bal
-
anced Pi filter which also provides noise isolation
from all other outlet banks.
5. Universal Coaxial
Connectors
3 pairs of bidirectional
protection circuits optimized for
satellite, cable, and antenna
TV signal lines.
3. Outlet Banks 3 and 4
Each bank features two switched outlets with
voltage regulation and linear filtration technology
(LiFT) controlled by the front panel Power Button
or the DC Trigger input. Banks 3 & 4 will turn on
immediately and turn off after a 10 second delay.
LiFT
EMI/RFI noise filtration is provided by a two-
stage balanced Pi filter which also provides noise
isolation from all other outlet banks.
2. Outlet Bank 5
Two switched, high-current outlets controlled by
the front panel Power Button or the DC Trigger in-
put. Bank 5 has a 5 second turn on delay and turns
off immediately upon shutdown. The High Current
outlets provide power from a low impedance noise
filtration circuit that does not limit the current to
your equipment. Its output is noise-isolated from all
other outlet banks.
6. Main Power Cord 10ft.
Must be plugged into a
properly wired & grounded
3-wire outlet
.
8. Bank 1 & 2 Indicator
Light
Normally ON, is lit when
there is power present
on the Bank 1 and 2
receptacles.
11. LAN Jacks
Protection circuits for 10/100 baseT Ethernet
lines. For the LAN 2 protected jacks, the
incoming LAN line MUST be plugged into the
LINE jack and the patch cord to the equipment
MUST be plugged into the EQUIP jack. For the
LAN 1 protected jacks the incoming LAN line
must be plugged into the LINE jack and the
equipment must be plugged into the gaming
jack on the front panel. 8 wire protection, 60V ±
5V clamping.
10. Voltage Sense Trigger
Input
3.5mm (1/8”) mono mini-plug.
Connect to a remote trigger
device that uses a DC output
to trigger a startup/shutdown
sequence.
7. Ground Lug:
Provides a common
grounding point for
equipment with separate
ground leads.
12. Phone Jacks
Protection circuits for standard
telephone or pay-per-view lines.
Phone circuit is autoresetting.
Incoming phone cord MUST be
plugged into the LINE jack. Patch
cords to the equipment (satellite
receiver, digital video recorder,
telephone, etc.) MUST be plugged
into the EQUIP jacks.
M5400-PM SPECIFICATIONS
UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
General________________________________________________________________
Dimensions
......................................
17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)
Weight
.........................................................................................................................
20 lbs.
AC Power_______________________________________________________________
Line Voltage
.........................................................................................................
120V, 60Hz
Total Current Capacity
......................................................................................
15 A (1800 W)
Voltage Protection Rating (UL1449 3rd Edition, 3,000A)
..............................................
500V
Protection Modes
.............................................................................................
L-N, L-G, N-G
Initial Clamping Level
........................................................................
200V Peak, 141 V RMS
Energy Dissipation
..............................................................................................
2350 Joules
Peak Impulse Current
.......................................................................................
75,000 Amps
Catastrophic Surge Circuit
................................................................................................
Yes
Thermal Fusing:
...............................................................................................................
Yes
Auto-resetting Over-voltage shutoff
............................................................
142 VAC ± 8 VAC
Auto-resetting Under-voltage shutoff
............................................................
86 VAC ± 6 VAC
EMI/RFI Noise Filtration___________________________________________________
Bank 1
...............................................................................
Up to -86 db (100 KHz – 2 MHz)
Bank 2
...............................................................................
Up to -91 db (100 KHz – 2 MHz)
Bank 3
...............................................................................
Up to -81 db (100 KHz – 2 MHz)
Bank 4
.............................................................................
Up to -100 db (100 KHz – 2 MHz)
Bank 5, High Current Outlets
............................................
Up to -81 db (100 KHz – 2 MHz)
Voltage Regulation (Banks 1-4)_____________________________________________
Power / Current……………………………………………………………
.....
....
1500 VA / 12A
Input Voltage Range:……………………………………………………...……...…100-136 VAC
Output Voltage Range:…………………………………………………………120 VAC ± 6 VAC
Buck Stage:……….………………………………..… reduces voltage in the 125-136 V range
Boost Stage 1:……………………………………….… boosts voltage in the 109-119 V range
Boost Stage 2:……………………………………..….. boosts voltage in the 100-109 V range
Design and specifications are subject to changes due to product upgrades and improvements.
DC Trigger Input__________________________________________________________
Jacks
......................................................................................
3.5mm (1/8”) mono mini-plug
Voltage and Polarity
......................................................................
3 - 24V DC, Bidirectional
Current Requirement
.................................................................
4.6 mA @3V, 58 mA @24V
DC Trigger Output________________________________________________________
Pass through
..........................................................................................................
no delay
Positive = Tip, Negative = Ring
LAN Protection___________________________________________________________
Clamping Level
......................................................................................................
60V ± 5V
Compatibility
...........................................................................................................
10/100bT
Connectors
..................................................................................................................
RJ-45
Wires Protected:
.......................................................................................................
8-Wires
USB Circuit_____________________________________________________________
Jacks
.........................................................................................................................
USB-A
Power Delivery
..........................................................................................
500 mA @ 5VDC
Telco Protection_________________________________________________________
Fuseless/Auto-resetting
..................................................................................................
Yes
Clamping Level
.............................................................................................................
260V
Capacitance
....................................................................................................
30pf (approx.)
Suppression Modes
..........................................................................
Metallic & Longitudinal
Wires Protected
.......................................................................................
2-Wire, Pins 4 & 5
Connectors
..................................................................................................................
RJ-11
Universal Coax Protection_________________________________________________
HD 1080 i/p Ready
...........................................................................................................
Yes
Shielded
..........................................................................................................................
Yes
Clamping Level
...............................................................................................................
75V
Frequency Range
......................................................................................
0 MHz - 2.2 GHz
Insertion Loss
..........................................................................................................
< 0.5 dB
Connectors
......................................................................................
Female “F”, Gold Plated
Bidirectional
.....................................................................................................................
Yes
MODEL M5400-PM
MASTER CARTON
UNIT CARTON
Dimensions
Weight
Dimensions
Weight
UPC
Qty
Dimensions
Weight
UPC
17” x 12.75” x 3.5”
20 lbs
23.25” x 19” x 9.25”
23 Lbs
0 50616 00815 0
1
23.75” x 19.75” x 10”
24 Lbs
5 00 50616 00815 5
4.1” H with feet
1690 Corporate Circle, Petaluma, CA. 94954
• 800-472-5555 • 707-283-5900
• Fax 707-283-5901
• ww
w.panamax.com
© 2009 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax
9. Voltage Sense Trigger
Output
3.5mm (1/8”) Mini-Plug jack.
Connecting a trigger wire to
the Voltage Sense Output jack
will allow the input signal to
pass through the M5400-PM to
control the startup/shutdown of
an additional device.
L591 REV. D 12/09