Panamax SM3-PRO Instruction Manual

Panamax SM3-PRO Manual

Panamax SM3-PRO manual content summary:

  • Panamax SM3-PRO | Instruction Manual - Page 1
    SM3-PRO Instructions BANK 1 BANK 2 VUONLSTAAFGEE WIRING FAULT BlueBOLT ACC 1 RESET ETHERNET 1 ETHERNET 2 ACC 2 SM3-PRO SYSTEM MANAGER Power Management with Remote Cloud-based Control and Monitoring. • 15 Amp Capacity • 3 Rear Panel Outlets in 2 Controllable and Monitored banks • Fully
  • Panamax SM3-PRO | Instruction Manual - Page 2
    including the Quick Start Guide: 1. SM3-PRO BANK 1 BANK 2 VUONLSTAAFGEE WIRING FAULT BlueBOLT ACC 1 RESET ETHERNET 1 ETHERNET 2 ACC 2 SM3-PRO SYSTEM MANAGER 2. Two Ft. detachable power cord. Retntion clip and 2 screws included. 3. Universal Mounting Bracket Panamax, 1800 S. McDowell Blvd
  • Panamax SM3-PRO | Instruction Manual - Page 3
    SM3-PRO will need to be repaired or replaced by Panamax if this occurs within the product's 3 year warranty. Sequential Startup/Shutdown: Audio/video systems and networking systems ACC 1 RESET ETHERNET 1 ETHERNET 2 ACC 2 SM3-PRO SYSTEM MANAGER 1. Install Mounting Bracket BANK 1 BANK 2 UNSAFE
  • Panamax SM3-PRO | Instruction Manual - Page 4
    Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions . 11. Refer all servicing to qualified service personnel. Servicing is required when the 8 6 RESET ETHERNET 1 ETHERNET 2 SM3-PRO SYSTEM MANAGER 1. Outlet Bank 1 and 2 Buttons
  • Panamax SM3-PRO | Instruction Manual - Page 5
    Overview WIRING FAULT BlueBOLT ACC 1 ACC 2 ETHERNET 1 ETHERNET 2 SM3-PRO SYSTEM MANAGER OUTLET 1 1 BANK 1 OUTLET 2 2 BANK 2 Outlets: your system safe and ensure compliance with Panamax's Connected Equipment Policy. COAX VOIP MODEM TEL LAN AC AC ROUTER WIFI SM3-PRO FRONT SM3-PRO BACK
  • Panamax SM3-PRO | Instruction Manual - Page 6
    ACC 2 SM3-PRO SYSTEM MANAGEERTHERNET 1 ETHERNET 2 SM3-PRO SYSTEM MANAGER Troubleshooting Q. Is your Power Management Component all of these questions and are still unable to connect your SM3-PRO component, please contact Panamax customer service at 1-800-472-5555. OUTLET 1 OUTLET 1 BANK 1
  • Panamax SM3-PRO | Instruction Manual - Page 7
    Off Delay: When a Turn Off Sequence is initiated, the outlet bank will turn OFF after the Turn Off Delay time. SM3-PRO Specifications AC POWER Operating Voltage 120 Vac / 60Hz Current Capacity 15 A UL 1449 Voltage Protection Rating 330V L-N, 400V L-G, 400V N-G UL
  • Panamax SM3-PRO | Instruction Manual - Page 8
    each outlet for an easy reference. BANK 1 BANK 2 UNSAFE VOLTAGE WIRING FAULT BlueBOLT ACC 1 ACC 2 RESET ETHERNET 1 ETHERNET 2 SM3-PRO SYSTEM MANAGER Outlet 1 Outlet 2 Outlet 3 OUTLET 1 BANK 1 OUTLET 2 BANK 2 OUTLET 3 120V / 60Hz 12A GROUND BANK 1 BANK 2 UNSAFE VOLTAGE WIRING FAULT
  • Panamax SM3-PRO | Instruction Manual - Page 9
    your router's connected devices table. In addition to providing external access and control via Panamax/Furman's hosted BlueBOLT platform, SM3-PRO may also be interfaced to control and automation systems on the local area network. Command, information and event messages are provided in standard
  • Panamax SM3-PRO | Instruction Manual - Page 10
    >3194548209 Send Information Query The Send Information query is used to retrieve the following system-level information from the SM3-PRO. Information elements are enclosed in the element. Query Response
  • Panamax SM3-PRO | Instruction Manual - Page 11
    bank ON For Core Brands use only Send Settings Query The Send Settings query is used to retrieve the device settings from the SM3-PRO such as outlet bank delays & trigger enable and display brightness level. Settings elements are enclosed in the element. Query Response
  • Panamax SM3-PRO | Instruction Manual - Page 12
    power OFF sequence 1 = Initiate power ON sequence Example: 1 Initiate a power ON sequence Reboot Command the SM3-PRO to reboot all of its systems, equivalent to pulling the plug and plugging it back into an electrical outlet. Upon reboot, all outlets will turn
  • Panamax SM3-PRO | Instruction Manual - Page 13
    the request. PORT is the UDP port number. Only one IP address / port event subscription is allowed. For example, to have event messages sent from a SM3-PRO with MAC address 10-65-A3-03-FF-FF to a control system at IP address 192.168.0.127 listening on port 1726:
  • Panamax SM3-PRO | Instruction Manual - Page 14
    Power Condition A Power Condition event is posted when the unit enters or recovers from over-voltage or under-voltage shutdown mode. Element Tag: Attribute: None Content 0 | 1 | 2 | 3 0 = power normal 1 = fault recovery 2 = under voltage 3 =
  • Panamax SM3-PRO | Instruction Manual - Page 15
    M4000-PRO performs instruction. CAUTION: Any changes or modifications not expressly approved by the guarantee of this device could void the user's authority to operate the equipment. Contacting Tech Support If you require technical support or equipment service, please contact Panamax Tech Support
  • Panamax SM3-PRO | Instruction Manual - Page 16
    SM3-PRO Limited Product Warranty and Connected Equipment Policy Information CAUTION! All Panamax Warranties and Connected Equipment Policies are valid only in the United States and Canada. CAUTION! Audio/Video, computer and/or telephone system installations can be very complex systems ; service calls
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Important:
You will need the SM3-PRO’s unique MAC Address and Challenge Key (provided on the 2 labels
attached to the cover of the Quick Start Guide which is included in the SM3-PRO packaging). One label is
permanently adhered to the Quick Start Guide and the other is removable for your convenience.
10005610-A
2/19/15
BANK 1
ETHERNET 1
SM3-PRO SYSTEM MANAGER
ETHERNET 2
BANK 2
UNSAFE
VOLTAGE
WIRING
FAULT
BlueBOLT
ACC 1
ACC 2
RESET
Power Management with Remote Cloud-based Control and Monitoring.
• 15 Amp Capacity
• 3 Rear Panel Outlets in 2 Controllable and Monitored banks
• Fully Programmable
Enabled
• AVM & Protect-or-Disconnect Circuitry
• 2-Port 10/100 Ethernet Switch
• Linear Filtration,-18.7dB@10kHz, -50.5dB@100kHz, -43.9dB@1MHz
• Accessory Inputs for External Sensors
• Rear Panel Circuit Breaker
• Universal Mounting Bracket Included
• Detachable 2 ft. Power Cord
SM3-PRO Instructions