Panasonic 36PET2U6 36PET2U6 Submittal Sheet - Page 2
Features, Operating Range, Indoor Air Intake Temp, Outdoor Air Intake Temp, Performance Data @ ARI
View all Panasonic 36PET2U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Performance Data @ ARI Standard Conditions (230/208V) Cooling Total Capacity (BTU/H) 32,600 (9,500 - 32,600) Sensible Capacity (BTU/H) 23,500 Latent Capacity (BTU/H) 9,100 SEER 18.0 Dehumidification (Pints/H) 6.5 Amps (A) 16.6/18.3 Power Inputs (W) 3,550/3,550 Outdoor Sound Rating (dB-A) High 49 Heating High Heating @47° Low Heating @17° Total Capacity (BTU/H) HSPF Amps (A) Power Inputs (W) Back-up Strip Heather (KW) Outdoor Sound Rating (dB-A) High 36,200 19,400 36,200 (8,000 - 36,200) 9.5 13.9/15.4 3,000/3,000 N/A 52 Features Controls Remote Controller Temperature Control Timer Night Setback Air Louver, Horizontal Air Louver, Vertical Power Failure Automatic Restart Heating/Cooling Automatic Changeover Self-Diagnosis Air Filter Microprocessor Remote Purchased Separately Thermostat 24 Hr. Program N/A Manual Automatic Built-In Built-In Built-In Washable, Anti-Mold Options Refrigerant Line Set Fresh Air Intake Econavi Avaliable With Use Of Indoor Frame Extension Condensate Drain Pump Non-Removeable Remo-con Bracket Available N/A CZ-RTC3,4,5 & CZ-CENCS1 N/A Optional Accessory Available Operating Range Cooling (Max) Cooling (Min) Heating (Max) Heating (Min) Indoor Air Intake Temp 95F DB/71F WB 67 DB/57F WB 80F DB/67F WB -DB/-WB Outdoor Air Intake Temp 115F DB 0F DB (No Lockout) 75F DB/65F WB (-4)F DB (No Lockout) Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon